Center of Ventilation-Methods of Calculation using Electrical Impedance Tomography and the Influence of Image Segmentation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F16%3A00304278" target="_blank" >RIV/68407700:21460/16:00304278 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-32703-7_241" target="_blank" >http://dx.doi.org/10.1007/978-3-319-32703-7_241</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-32703-7_241" target="_blank" >10.1007/978-3-319-32703-7_241</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Center of Ventilation-Methods of Calculation using Electrical Impedance Tomography and the Influence of Image Segmentation
Popis výsledku v původním jazyce
Electrical impedance tomography (EIT) is a promising non-invasive, radiation-free imaging modality. Using EIT-derived index Center of ventilation (CoV), ventral-to-dorsal shifts in distribution of lung ventilation can be assessed. The methods of CoV calculation differ among authors and so does the segmentation of EIT images from which the CoV is calculated. The aim of this study is to compare the values of CoV obtained using different algorithms, applied in variously segmented EIT images. An animal trial (n=4) with anesthetized mechanically ventilated pigs was conducted. In one animal, acute respiratory distress syndrome (ARDS) was induced by repeated whole lung lavage. Incremental steps in positive end-expiratory pressure (PEEP), each with a value of 5 cmH(2)O (or 4 cmH(2)O in the ARDS model), were performed to reach total PEEP level of 25 cmH(2)O (or 22 cmH(2)O in the ARDS model). EIT data were acquired continuously during this PEEP trial. From each PEEP level, 30 tidal variation (TV) images were used for analysis. Functional regions of interest (ROI) were defined based on the standard deviation (SD) of pixel values, using threshold 15%-35% of maximum pixel SD. The results of this study show that there might be statistically significant differences between the values obtained using different methods for calculation of CoV. The differences occured in healthy animals as well as in the ARDS model. Both investigated algorithms are relatively insensitive to the image segmentation.
Název v anglickém jazyce
Center of Ventilation-Methods of Calculation using Electrical Impedance Tomography and the Influence of Image Segmentation
Popis výsledku anglicky
Electrical impedance tomography (EIT) is a promising non-invasive, radiation-free imaging modality. Using EIT-derived index Center of ventilation (CoV), ventral-to-dorsal shifts in distribution of lung ventilation can be assessed. The methods of CoV calculation differ among authors and so does the segmentation of EIT images from which the CoV is calculated. The aim of this study is to compare the values of CoV obtained using different algorithms, applied in variously segmented EIT images. An animal trial (n=4) with anesthetized mechanically ventilated pigs was conducted. In one animal, acute respiratory distress syndrome (ARDS) was induced by repeated whole lung lavage. Incremental steps in positive end-expiratory pressure (PEEP), each with a value of 5 cmH(2)O (or 4 cmH(2)O in the ARDS model), were performed to reach total PEEP level of 25 cmH(2)O (or 22 cmH(2)O in the ARDS model). EIT data were acquired continuously during this PEEP trial. From each PEEP level, 30 tidal variation (TV) images were used for analysis. Functional regions of interest (ROI) were defined based on the standard deviation (SD) of pixel values, using threshold 15%-35% of maximum pixel SD. The results of this study show that there might be statistically significant differences between the values obtained using different methods for calculation of CoV. The differences occured in healthy animals as well as in the ARDS model. Both investigated algorithms are relatively insensitive to the image segmentation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016
ISBN
978-3-319-32703-7
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1258-1263
Název nakladatele
Springer
Místo vydání
New York
Místo konání akce
Paphos
Datum konání akce
31. 3. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000376283000241