Electronic hand grip dynamometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F17%3A00315712" target="_blank" >RIV/68407700:21460/17:00315712 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EHB.2017.7995408" target="_blank" >http://dx.doi.org/10.1109/EHB.2017.7995408</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EHB.2017.7995408" target="_blank" >10.1109/EHB.2017.7995408</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electronic hand grip dynamometer
Popis výsledku v původním jazyce
Main purpose of this paper is to describe a propose and compile a dynamometric measurement system which would measure the isometric force of a handgrip. Although, in the practice, there have already been the mechanic hand dynamometers which could evaluate only a limited amount of information, precisely the maximum strength of a handgrip, our aim is to compile the full electronic hand dynamometer. This work is focused on a design of an appropriate hardware and software for processing and evaluating of the measured data. By the software is able to display the dynamometric graph and also the actual and the maximal strength. It is possible to count maximal gradient of the strength and all these data could be stored in a file. The created dynamometric system might be used in the clinical practice, more accurately on the rehabilitation department where it could replace the current mechanical hand dynamometers or for patients with Parkinson's disease where is possible to evaluate a tremor.
Název v anglickém jazyce
Electronic hand grip dynamometer
Popis výsledku anglicky
Main purpose of this paper is to describe a propose and compile a dynamometric measurement system which would measure the isometric force of a handgrip. Although, in the practice, there have already been the mechanic hand dynamometers which could evaluate only a limited amount of information, precisely the maximum strength of a handgrip, our aim is to compile the full electronic hand dynamometer. This work is focused on a design of an appropriate hardware and software for processing and evaluating of the measured data. By the software is able to display the dynamometric graph and also the actual and the maximal strength. It is possible to count maximal gradient of the strength and all these data could be stored in a file. The created dynamometric system might be used in the clinical practice, more accurately on the rehabilitation department where it could replace the current mechanical hand dynamometers or for patients with Parkinson's disease where is possible to evaluate a tremor.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2017 E-Health and Bioengineering Conference (EHB)
ISBN
978-1-5386-0358-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
249-252
Název nakladatele
Gr. T. Popa University of Medicine and Pharmacy
Místo vydání
Iasi
Místo konání akce
Sinaia
Datum konání akce
22. 6. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—