Determining ablation depth and ablation threshold for tissue using CT imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F18%3A00326346" target="_blank" >RIV/68407700:21460/18:00326346 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determining ablation depth and ablation threshold for tissue using CT imaging
Popis výsledku v původním jazyce
Photoablation occurs in laser-irradiated tissue when the laser parameters are adjusted appropriately. This effectively removes the target tissue directly by breaking the molecular bonds and expunging the decomposed fragments. Excimer lasers in pulse mode emit photons carrying enough energy to break the bonds. To analyze the profile of ablation craters and their depth, a new method using CT imaging was developed and verified. Values of depth determined through this method were compared with values obtained by other methods. The aim of our experiments was to determine the ablation depth – the thickness of the layer removed with a single laser pulse in photoablation for different types of tissue. It was determined by dividing the ablation crater depth values obtained through CT imaging by the number of applied laser pulses. Experimentally obtained values of all measured variables are in accordance with values obtained in previous experiments, and with values available in current publications.
Název v anglickém jazyce
Determining ablation depth and ablation threshold for tissue using CT imaging
Popis výsledku anglicky
Photoablation occurs in laser-irradiated tissue when the laser parameters are adjusted appropriately. This effectively removes the target tissue directly by breaking the molecular bonds and expunging the decomposed fragments. Excimer lasers in pulse mode emit photons carrying enough energy to break the bonds. To analyze the profile of ablation craters and their depth, a new method using CT imaging was developed and verified. Values of depth determined through this method were compared with values obtained by other methods. The aim of our experiments was to determine the ablation depth – the thickness of the layer removed with a single laser pulse in photoablation for different types of tissue. It was determined by dividing the ablation crater depth values obtained through CT imaging by the number of applied laser pulses. Experimentally obtained values of all measured variables are in accordance with values obtained in previous experiments, and with values available in current publications.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů