Electrical Source Imaging in Rats: Cortical EEG Performance and Limitations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F18%3A00329752" target="_blank" >RIV/68407700:21460/18:00329752 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/18:PU136154
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrical Source Imaging in Rats: Cortical EEG Performance and Limitations
Popis výsledku v původním jazyce
The goal of the present work is to estimate electric activity within the brain volume based on measured potentials on the rats brain surface. At first, we calculated and analyzed sensitivity volume profile of cortical electrode pairs to address the cortical electrode positioning. Sensitivity volume profiles change rapidly with decreasing of expected minimal depth of the sources. Moreover, the profiles become unreliable in case of very small expected minimal depths, which is, unfortunately, the case of cortical electroencephalogram (EEG). This result was obtained in both analytical and numerical models. Second, appropriate regularization and normalization routines were implemented for minimum norm estimate and beam-forming methods. Third, the inverse methods were applied to localize simulated brain deep sources based on the twelve electrode cortical EEG system.
Název v anglickém jazyce
Electrical Source Imaging in Rats: Cortical EEG Performance and Limitations
Popis výsledku anglicky
The goal of the present work is to estimate electric activity within the brain volume based on measured potentials on the rats brain surface. At first, we calculated and analyzed sensitivity volume profile of cortical electrode pairs to address the cortical electrode positioning. Sensitivity volume profiles change rapidly with decreasing of expected minimal depth of the sources. Moreover, the profiles become unreliable in case of very small expected minimal depths, which is, unfortunately, the case of cortical electroencephalogram (EEG). This result was obtained in both analytical and numerical models. Second, appropriate regularization and normalization routines were implemented for minimum norm estimate and beam-forming methods. Third, the inverse methods were applied to localize simulated brain deep sources based on the twelve electrode cortical EEG system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-16218S" target="_blank" >GA18-16218S: Elektromagnetické modely zvířecích mozků</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 International Workshop on Computing, Electromagnetics, and Machine Intelligence (CEMi)
ISBN
978-1-5386-7845-9
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
45-46
Název nakladatele
IEEE
Místo vydání
—
Místo konání akce
Stellenbosch
Datum konání akce
21. 11. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000458403200023