The potential of constrained SAR focusing for hyperthermia treatment planning: analysis for the head & neck region
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00326454" target="_blank" >RIV/68407700:21460/19:00326454 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1361-6560/aaf0c4" target="_blank" >https://doi.org/10.1088/1361-6560/aaf0c4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1361-6560/aaf0c4" target="_blank" >10.1088/1361-6560/aaf0c4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The potential of constrained SAR focusing for hyperthermia treatment planning: analysis for the head & neck region
Popis výsledku v původním jazyce
Clinical trials have shown that hyperthermia is a potent adjuvant to conventional cancer treatments, but the temperatures currently achieved in the clinic are still suboptimal. Hyperthermia treatment planning simulations have potential to improve the heating profile of phased-array applicators. An important open challenge is the development of an effective optimization procedure that enables uniform heating of the target region while keeping temperature below a threshold in healthy tissues. In this work, we analyzed the effectiveness and efficiency of a recently proposed optimization approach, i.e. focusing via constrained power optimization (FOCO), using 3D simulations of twelve clinical patient specific models. FOCO performance was compared against a clinically used particle swarm based optimization approach. Evaluation metrics were target coverage at the 25% iso-SAR level, target hotspot quotient, median target temperature (T50) and computational requirements. Our results show that, on average, constrained power focusing performs slightly better than the clinical benchmark (T50 °C), but outperforms this clinical benchmark for large target volumes (40 cm, T50 °C). In addition, the results are achieved in a shorter time (%) and are repeatable because the approach is formulated as a convex optimization problem.
Název v anglickém jazyce
The potential of constrained SAR focusing for hyperthermia treatment planning: analysis for the head & neck region
Popis výsledku anglicky
Clinical trials have shown that hyperthermia is a potent adjuvant to conventional cancer treatments, but the temperatures currently achieved in the clinic are still suboptimal. Hyperthermia treatment planning simulations have potential to improve the heating profile of phased-array applicators. An important open challenge is the development of an effective optimization procedure that enables uniform heating of the target region while keeping temperature below a threshold in healthy tissues. In this work, we analyzed the effectiveness and efficiency of a recently proposed optimization approach, i.e. focusing via constrained power optimization (FOCO), using 3D simulations of twelve clinical patient specific models. FOCO performance was compared against a clinically used particle swarm based optimization approach. Evaluation metrics were target coverage at the 25% iso-SAR level, target hotspot quotient, median target temperature (T50) and computational requirements. Our results show that, on average, constrained power focusing performs slightly better than the clinical benchmark (T50 °C), but outperforms this clinical benchmark for large target volumes (40 cm, T50 °C). In addition, the results are achieved in a shorter time (%) and are repeatable because the approach is formulated as a convex optimization problem.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physics in Medicine and Biology
ISSN
0031-9155
e-ISSN
1361-6560
Svazek periodika
64
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000454239200006
EID výsledku v databázi Scopus
2-s2.0-85058918246