Problems in meeting regulatory requirements related to the skin dose
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00336109" target="_blank" >RIV/68407700:21460/19:00336109 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Problems in meeting regulatory requirements related to the skin dose
Popis výsledku v původním jazyce
In accordance with the general recommendations of the International Commission on Radiological Protection (ICRP) stating that the dose limit for the skin dose in terms of the relevant equivalent dose is not supposed to exceed 500 mSv in a year. Since the actual equivalent dose has to be averaged over 1 cm2 area of skin regardless of the area exposed, such a requirement is impossible to verify based on a routine monitoring relying on the reading of finger dosimeter. This dosimeter, usually a TLD, gives the information about personal dose equivalent at the depth of 0.07 mm but its position is generally not at the point where with maximum exposure. Averaging TLD reading over the prescribed area is also questionable. The paper is aimed at the assessment of the correction factors which would convert the TLD reading into the recommended quantity so that the compliance with dose limit could be confronted.
Název v anglickém jazyce
Problems in meeting regulatory requirements related to the skin dose
Popis výsledku anglicky
In accordance with the general recommendations of the International Commission on Radiological Protection (ICRP) stating that the dose limit for the skin dose in terms of the relevant equivalent dose is not supposed to exceed 500 mSv in a year. Since the actual equivalent dose has to be averaged over 1 cm2 area of skin regardless of the area exposed, such a requirement is impossible to verify based on a routine monitoring relying on the reading of finger dosimeter. This dosimeter, usually a TLD, gives the information about personal dose equivalent at the depth of 0.07 mm but its position is generally not at the point where with maximum exposure. Averaging TLD reading over the prescribed area is also questionable. The paper is aimed at the assessment of the correction factors which would convert the TLD reading into the recommended quantity so that the compliance with dose limit could be confronted.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
30305 - Occupational health
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů