Evaluating of Spatial and Contrast Resolution Ability of 2D Microwave Imaging System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00340887" target="_blank" >RIV/68407700:21460/19:00340887 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017663" target="_blank" >http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017663</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017663" target="_blank" >10.1109/PIERS-Spring46901.2019.9017663</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluating of Spatial and Contrast Resolution Ability of 2D Microwave Imaging System
Popis výsledku v původním jazyce
Microwave Imaging method can be applicable for early brain stroke detection and can help to eliminate the time between onset of the stroke and its treatment. Base on variation in dielectric parameters of stroke-hit part of the brain and its surroundings the haemorrhagic or ischemic stroke can be differentiate, respectively. The goal of this contribution is to evaluate spatial and contrast resolution of 2D MWI system designed at CTU FBME based on synthetic, numerical data. These results can help to better define MWI method in terms of imaging technique and can provide a great base for future experimental evaluation of spatial and contrast resolution ability of MWI systems. Also, can provide information which will be valuable for determination of ideal operating frequency for MWI method or frequency range, respectively
Název v anglickém jazyce
Evaluating of Spatial and Contrast Resolution Ability of 2D Microwave Imaging System
Popis výsledku anglicky
Microwave Imaging method can be applicable for early brain stroke detection and can help to eliminate the time between onset of the stroke and its treatment. Base on variation in dielectric parameters of stroke-hit part of the brain and its surroundings the haemorrhagic or ischemic stroke can be differentiate, respectively. The goal of this contribution is to evaluate spatial and contrast resolution of 2D MWI system designed at CTU FBME based on synthetic, numerical data. These results can help to better define MWI method in terms of imaging technique and can provide a great base for future experimental evaluation of spatial and contrast resolution ability of MWI systems. Also, can provide information which will be valuable for determination of ideal operating frequency for MWI method or frequency range, respectively
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ17-00477Y" target="_blank" >GJ17-00477Y: Fyzikální podstata interakcí EM pole generovaného MTM strukturami s lidským tělem a studie možnosti jejich perspektivního využití v medicíně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium
ISBN
9781728134031
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1428-1433
Název nakladatele
Institute of Electrical and Electronics Engineers, Inc.
Místo vydání
—
Místo konání akce
Řím
Datum konání akce
17. 6. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000550769301072