0.5-V High Linear and Wide Tunable OTA for Biomedical Applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F21%3A00357211" target="_blank" >RIV/68407700:21460/21:00357211 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/21:PU141312
Výsledek na webu
<a href="https://doi.org/10.1109/ACCESS.2021.3098183" target="_blank" >https://doi.org/10.1109/ACCESS.2021.3098183</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ACCESS.2021.3098183" target="_blank" >10.1109/ACCESS.2021.3098183</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
0.5-V High Linear and Wide Tunable OTA for Biomedical Applications
Popis výsledku v původním jazyce
This paper presents a low-voltage nano-power multiple-input operational transconductance amplifier (MI-OTA) with high linearity performance and increased input voltage swing. The enhanced performances are achieved thanks to employing several techniques as the bulk-driven, source-degeneration, self-cascode and negative conductance along with the concept of the input signal attenuation formed by multiple-input MOS transistor. The MI-OTA is widely tunable that serves for biological signals processing. A 3rd-order Butterworth band-pass filter (BPF) for electrocardiogram (ECG) signal processing with 55.8 dB dynamic rang is presented. The MI-OTA circuit is designed for 0.5V voltage supply and offers a 0.22% total harmonic distortion (THD) for 0.2V(pp) input signal with total power consumption of 13.4nW. Extensive simulation results including Monte Carlo analysis and process, voltage, temperature (PVT) corners using the 0.18 mu m CMOS technology from TSMC confirm the characteristics of the proposed MI-OTA and the filter.
Název v anglickém jazyce
0.5-V High Linear and Wide Tunable OTA for Biomedical Applications
Popis výsledku anglicky
This paper presents a low-voltage nano-power multiple-input operational transconductance amplifier (MI-OTA) with high linearity performance and increased input voltage swing. The enhanced performances are achieved thanks to employing several techniques as the bulk-driven, source-degeneration, self-cascode and negative conductance along with the concept of the input signal attenuation formed by multiple-input MOS transistor. The MI-OTA is widely tunable that serves for biological signals processing. A 3rd-order Butterworth band-pass filter (BPF) for electrocardiogram (ECG) signal processing with 55.8 dB dynamic rang is presented. The MI-OTA circuit is designed for 0.5V voltage supply and offers a 0.22% total harmonic distortion (THD) for 0.2V(pp) input signal with total power consumption of 13.4nW. Extensive simulation results including Monte Carlo analysis and process, voltage, temperature (PVT) corners using the 0.18 mu m CMOS technology from TSMC confirm the characteristics of the proposed MI-OTA and the filter.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Access
ISSN
2169-3536
e-ISSN
2169-3536
Svazek periodika
9
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
103784-103794
Kód UT WoS článku
000678314900001
EID výsledku v databázi Scopus
2-s2.0-85111037773