ANALYSIS OF CORNEAL ANTEROPOSTERIOR RATIO OF OPTICAL POWER USING OCT ANALÝZA PŘEDOZADNÍHO POMĚRU OPTICKÉ MOHUTNOSTI ROHOVKY POMOCÍ OCT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F22%3A00360662" target="_blank" >RIV/68407700:21460/22:00360662 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.31348/2022/23" target="_blank" >https://doi.org/10.31348/2022/23</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.31348/2022/23" target="_blank" >10.31348/2022/23</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ANALYSIS OF CORNEAL ANTEROPOSTERIOR RATIO OF OPTICAL POWER USING OCT ANALÝZA PŘEDOZADNÍHO POMĚRU OPTICKÉ MOHUTNOSTI ROHOVKY POMOCÍ OCT
Popis výsledku v původním jazyce
Aims: The aim of the study was to analyse the values of the anteroposterior corneal optical power ratio (AP ratio), to compare the resulting values with those of theoretical models of the eye, and to define the effect of using an individual ratio value on the approximation of the total corneal power. Material and Methods: A total of 406 eyes were included. Each patient underwent an OCT (RTVue XR) examination, according to which the AP ratio of the cornea was determined, as well as the biometric parameters of the eye (Lenstar LS900). The correlation between the biometric parameters of the eye and the individual AP ratio values was evaluated using Pearson’s correlation coefficient. In the analysis, the AP ratio results were compared with selected schematic models of the eye. Using Gaussian equations, a theoretical calculation of the total corneal optical power (KG) was performed, by fitting the AP ratio value and comparing it with the actually measured total corneal power (TCP). Results: The mean value of the individually determined AP ratio was 1.17 ±0.02. The most frequently represented interval (33.74 %) was 1.17 to 1.18 AP ratio values, with the vast majority of eyes (79.56 %) in the range of 1.15 to 1.20. Individual values of total corneal optical power were statistically significantly different (p < 0.05) from the theoretical values of TCP (except in the Liu-Brennan eye model, where p = 0.06). The lowest mean difference of values was found for the Navarro schematic model. The dependence of the measured AP ratio values and biometric parameters reached a moderate negative correlation (r = -0.50 for p < 0.05) with the parameter corneal posterior surface curvature (Rp), as well as a weak negative correlation with limbal diameter WtW (r = -0.26 for p < 0.05) and a weak positive correlation with central corneal thickness CCT (r = 0.17 for p < 0.05). Conclusion: The assumption of a constant value of the AP ratio according to the selected schematic models of the eye is statistically significantly different from the actual measured values and was defined to have only a negative weak correlation with the size of the limbus diameter. Using the resulting average value of the determined AP ratio (1.17 ±0.02), a lower difference between real and calculated total corneal optical power was achieved.
Název v anglickém jazyce
ANALYSIS OF CORNEAL ANTEROPOSTERIOR RATIO OF OPTICAL POWER USING OCT ANALÝZA PŘEDOZADNÍHO POMĚRU OPTICKÉ MOHUTNOSTI ROHOVKY POMOCÍ OCT
Popis výsledku anglicky
Aims: The aim of the study was to analyse the values of the anteroposterior corneal optical power ratio (AP ratio), to compare the resulting values with those of theoretical models of the eye, and to define the effect of using an individual ratio value on the approximation of the total corneal power. Material and Methods: A total of 406 eyes were included. Each patient underwent an OCT (RTVue XR) examination, according to which the AP ratio of the cornea was determined, as well as the biometric parameters of the eye (Lenstar LS900). The correlation between the biometric parameters of the eye and the individual AP ratio values was evaluated using Pearson’s correlation coefficient. In the analysis, the AP ratio results were compared with selected schematic models of the eye. Using Gaussian equations, a theoretical calculation of the total corneal optical power (KG) was performed, by fitting the AP ratio value and comparing it with the actually measured total corneal power (TCP). Results: The mean value of the individually determined AP ratio was 1.17 ±0.02. The most frequently represented interval (33.74 %) was 1.17 to 1.18 AP ratio values, with the vast majority of eyes (79.56 %) in the range of 1.15 to 1.20. Individual values of total corneal optical power were statistically significantly different (p < 0.05) from the theoretical values of TCP (except in the Liu-Brennan eye model, where p = 0.06). The lowest mean difference of values was found for the Navarro schematic model. The dependence of the measured AP ratio values and biometric parameters reached a moderate negative correlation (r = -0.50 for p < 0.05) with the parameter corneal posterior surface curvature (Rp), as well as a weak negative correlation with limbal diameter WtW (r = -0.26 for p < 0.05) and a weak positive correlation with central corneal thickness CCT (r = 0.17 for p < 0.05). Conclusion: The assumption of a constant value of the AP ratio according to the selected schematic models of the eye is statistically significantly different from the actual measured values and was defined to have only a negative weak correlation with the size of the limbus diameter. Using the resulting average value of the determined AP ratio (1.17 ±0.02), a lower difference between real and calculated total corneal optical power was achieved.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Česká a slovenská oftalmologie
ISSN
1211-9059
e-ISSN
—
Svazek periodika
78
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
228-232
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85139627239