Vliv okolních staveb na místní tlaky větru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F05%3A07117331" target="_blank" >RIV/68407700:21610/05:07117331 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of Surroundings on Wind Induced Local Pressures
Popis výsledku v původním jazyce
Listed in this contribution, there are the pressure coefficient measurement results gained on a model high building, scaled 1:400 in lengths. Measuring was carried out in the wind tunnel with the model atmospheric boundary layer of VZLÚ/KÚ ČVUT with boththe standalone model and the model in a built-up area. Using the measurements, the mean pressure coefficient values and the pseudo-steady coefficient values were determined. Using the integration across a square area, the measurements were entered intothe calculation of their estimates for the entire walls and different wind directions. The contribution comprises the comparison between both above-mentioned coefficients and assesses how the surrounding buildings can influence their size.
Název v anglickém jazyce
Effects of Surroundings on Wind Induced Local Pressures
Popis výsledku anglicky
Listed in this contribution, there are the pressure coefficient measurement results gained on a model high building, scaled 1:400 in lengths. Measuring was carried out in the wind tunnel with the model atmospheric boundary layer of VZLÚ/KÚ ČVUT with boththe standalone model and the model in a built-up area. Using the measurements, the mean pressure coefficient values and the pseudo-steady coefficient values were determined. Using the integration across a square area, the measurements were entered intothe calculation of their estimates for the entire walls and different wind directions. The contribution comprises the comparison between both above-mentioned coefficients and assesses how the surrounding buildings can influence their size.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F03%2F1395" target="_blank" >GA103/03/1395: Spolehlivost modelového měření místních tlaků ve větrném tunelu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-86246-26-4
Místo vydání
Prague
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno