Durability Assessment of Large Surfaces
Popis výsledku
Identifikátory výsledku
Kód výsledku v IS VaVaI
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Durability Assessment of Large Surfaces
Popis výsledku v původním jazyce
Initiation limit states defined in ISO 13823 (2008) may be of uttermost importance for serviceability as well as ultimate limit states of civil engineering structures. Durability assessments and optimisation studies may be difficult as basic variables are often random quantities with a considerable spatial variability. Applications of common discretisation techniques may be time consuming, particularly in case of optimisation studies. A simplified probabilistic model for spatial variability is thus adopted from the bulletin of fib (2006), enabling durability analysis using efficient FORM/SORM methods. Basic features of the model are illustrated by a simplified example.A case study is then focused on a cooling tower exposed to carbonation. It appears that the reliability level associated with durability is significantly affected by the model uncertainties that should be further investigated. The study reveals that the effect of a size of the surface area on the optimum concrete cover an
Název v anglickém jazyce
Durability Assessment of Large Surfaces
Popis výsledku anglicky
Initiation limit states defined in ISO 13823 (2008) may be of uttermost importance for serviceability as well as ultimate limit states of civil engineering structures. Durability assessments and optimisation studies may be difficult as basic variables are often random quantities with a considerable spatial variability. Applications of common discretisation techniques may be time consuming, particularly in case of optimisation studies. A simplified probabilistic model for spatial variability is thus adopted from the bulletin of fib (2006), enabling durability analysis using efficient FORM/SORM methods. Basic features of the model are illustrated by a simplified example.A case study is then focused on a cooling tower exposed to carbonation. It appears that the reliability level associated with durability is significantly affected by the model uncertainties that should be further investigated. The study reveals that the effect of a size of the surface area on the optimum concrete cover an
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GJ - Choroby a škůdci zvířat, veterinární medicina
OECD FORD obor
—
Návaznosti výsledku
Projekt
GBP105/12/G059: Kumulativní časově závislé procesy ve stavebních materiálech a konstrukcích
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Safety, Reliability, Risk and Life-Cycle Performance of Structures and Infrastructures
ISBN
978-1-138-00086-5
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
2665-2671
Název nakladatele
CRC Press/Balkema
Místo vydání
Leiden
Místo konání akce
New York
Datum konání akce
16. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—
Druh výsledku
D - Stať ve sborníku
CEP
GJ - Choroby a škůdci zvířat, veterinární medicina
Rok uplatnění
2013