Experimental tests of vater vapour permeability of plasters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F16%3A00300690" target="_blank" >RIV/68407700:21610/16:00300690 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.researchgate.net/publication/306071265_Experimental_Tests_of_Water_Vapour_Permeability_of_Plasters" target="_blank" >https://www.researchgate.net/publication/306071265_Experimental_Tests_of_Water_Vapour_Permeability_of_Plasters</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/MSF.865.151" target="_blank" >10.4028/www.scientific.net/MSF.865.151</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental tests of vater vapour permeability of plasters
Popis výsledku v původním jazyce
In the paper there are summarized results of diffusion properties of mortars. Water vapour permeability represented by diffusion thicknesses and water vapour resistance factors are except mechanical properties the most important physical parameters of historic buildings. These parameters are influenced by border conditions among that mainly temperature, relative humidity and barometric air pressure belong. It is necessary to know these parameters to understand a material behaviour after a flood. They are decisive for a determination how quick a diffusion speed rate will be and a drying process will take. Everything depends on a type of binder, a material of a structure itself and primarily on properties of mortar and plaster and finishing. After a flood it is necessary to know when users of buildings can start to make rehabilitations and which of them are proper for particular material and when can return to their homes.
Název v anglickém jazyce
Experimental tests of vater vapour permeability of plasters
Popis výsledku anglicky
In the paper there are summarized results of diffusion properties of mortars. Water vapour permeability represented by diffusion thicknesses and water vapour resistance factors are except mechanical properties the most important physical parameters of historic buildings. These parameters are influenced by border conditions among that mainly temperature, relative humidity and barometric air pressure belong. It is necessary to know these parameters to understand a material behaviour after a flood. They are decisive for a determination how quick a diffusion speed rate will be and a drying process will take. Everything depends on a type of binder, a material of a structure itself and primarily on properties of mortar and plaster and finishing. After a flood it is necessary to know when users of buildings can start to make rehabilitations and which of them are proper for particular material and when can return to their homes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP105%2F12%2FG059" target="_blank" >GBP105/12/G059: Kumulativní časově závislé procesy ve stavebních materiálech a konstrukcích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Silicon Carbide and Related Materials 2015
ISBN
978-3-0357-1042-7
ISSN
0255-5476
e-ISSN
1662-9752
Počet stran výsledku
6
Strana od-do
151-156
Název nakladatele
Trans Tech Publications Ltd.
Místo vydání
Pfaffikon
Místo konání akce
Giardini Naxos
Datum konání akce
4. 10. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—