Renovation and Design of Double Casement Windows with Regard to the Occurrence of Water Vapour Condensation or Mould on the Interior Surface of the Window Jamb
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F17%3A00314824" target="_blank" >RIV/68407700:21610/17:00314824 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/251/1/012101" target="_blank" >http://dx.doi.org/10.1088/1757-899X/251/1/012101</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/251/1/012101" target="_blank" >10.1088/1757-899X/251/1/012101</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Renovation and Design of Double Casement Windows with Regard to the Occurrence of Water Vapour Condensation or Mould on the Interior Surface of the Window Jamb
Popis výsledku v původním jazyce
The condensation of water vapour on the interior surface is an indicator of construction dysfunction or ignoring of the surroundings temperature and relative humidity. This paper deals with analysis of the occurrence of condensation on the jamb of double casement windows (windows with two window casements). More precisely, this is a surface in the interior where water vapour condensation or mould occur. For the renovation of existing double casement windows, there are different solutions based on window design: application of double insulating glazing on the interior window casement, application of double insulating glazing on the exterior casement, or installation of a simple window. We first describe measurement of an existing double casement window located in a mountain cottage. Second, the results and comparison of 2D thermal model of different types of double casement window construction. Also, the external insulation of the peripheral wall was included in the model.
Název v anglickém jazyce
Renovation and Design of Double Casement Windows with Regard to the Occurrence of Water Vapour Condensation or Mould on the Interior Surface of the Window Jamb
Popis výsledku anglicky
The condensation of water vapour on the interior surface is an indicator of construction dysfunction or ignoring of the surroundings temperature and relative humidity. This paper deals with analysis of the occurrence of condensation on the jamb of double casement windows (windows with two window casements). More precisely, this is a surface in the interior where water vapour condensation or mould occur. For the renovation of existing double casement windows, there are different solutions based on window design: application of double insulating glazing on the interior window casement, application of double insulating glazing on the exterior casement, or installation of a simple window. We first describe measurement of an existing double casement window located in a mountain cottage. Second, the results and comparison of 2D thermal model of different types of double casement window construction. Also, the external insulation of the peripheral wall was included in the model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
1757-899X
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
IOP Publishing Ltd
Místo vydání
Bristol
Místo konání akce
Riga
Datum konání akce
27. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000419383500101