Problems connected with use of hot-dip galvanized reinforcement in concrete elements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F17%3A00315785" target="_blank" >RIV/68407700:21610/17:00315785 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.proeng.2017.02.086" target="_blank" >http://dx.doi.org/10.1016/j.proeng.2017.02.086</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2017.02.086" target="_blank" >10.1016/j.proeng.2017.02.086</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Problems connected with use of hot-dip galvanized reinforcement in concrete elements
Popis výsledku v původním jazyce
The goal of this article is to evaluate risks arising from using hot-dip galvanized reinforcement in concrete elements. The article provides detailed summary of current experimental activities but also earlier positive remarks about applicability of hot-dip galvanized reinforcement, mainly from the perspective of corrosion and bond strength with concrete. Based on previously obtained data, the article disproves barrier effect of zinc coating on base steel. The reason is the initial corrosion reaction of zinc coating in fresh concrete producing hydrogen. Further data prove that forming hydrogen irreversibly increases porosity of cement on reinforcement/concrete interface which can significantly reduce bond strength. Sufficient filling of pores by zinc corrosion product could not be confirmed.
Název v anglickém jazyce
Problems connected with use of hot-dip galvanized reinforcement in concrete elements
Popis výsledku anglicky
The goal of this article is to evaluate risks arising from using hot-dip galvanized reinforcement in concrete elements. The article provides detailed summary of current experimental activities but also earlier positive remarks about applicability of hot-dip galvanized reinforcement, mainly from the perspective of corrosion and bond strength with concrete. Based on previously obtained data, the article disproves barrier effect of zinc coating on base steel. The reason is the initial corrosion reaction of zinc coating in fresh concrete producing hydrogen. Further data prove that forming hydrogen irreversibly increases porosity of cement on reinforcement/concrete interface which can significantly reduce bond strength. Sufficient filling of pores by zinc corrosion product could not be confirmed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20506 - Coating and films
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-20856S" target="_blank" >GA14-20856S: Kinetika korozních dějů a transportu korozních médií v ultra-vysokopevnostních betonech (UHPC)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Procedia Engineering
ISBN
—
ISSN
1877-7058
e-ISSN
1877-7058
Počet stran výsledku
8
Strana od-do
859-866
Název nakladatele
Elsevier
Místo vydání
Lausanne
Místo konání akce
Vilnius
Datum konání akce
26. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000410919400112