Corrosion of Zinc Dust in Cement Paste–Evaluation of Hydrogen Gas Evolution Time Period
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F22%3A00361240" target="_blank" >RIV/68407700:21610/22:00361240 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.4028/p-ui99y8" target="_blank" >https://doi.org/10.4028/p-ui99y8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/p-ui99y8" target="_blank" >10.4028/p-ui99y8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Corrosion of Zinc Dust in Cement Paste–Evaluation of Hydrogen Gas Evolution Time Period
Popis výsledku v původním jazyce
Presented paper studies corrosion kinetics of zinc dust in cement paste using acoustic emission and impedance spectroscopy (measurement of electric resistance of compact samples) method. The focus is on determination of hydrogen evolution period and its effect on porous structure of cement paste. Results more or less confirm results of other authors that the corrosion products of zinc are unable to efficiently fill the pores forming due to hydrogen. Time period of hydrogen evolution - cathodic corrosion reaction of zinc in alkaline environment of cement paste can be up to several days long. Keywords: hot-dip galvanized reinforcement, corrosion of zinc dust, acoustic emission method, hydrogen evolution, porosity of cement paste, electrochemical impedance spectroscopy
Název v anglickém jazyce
Corrosion of Zinc Dust in Cement Paste–Evaluation of Hydrogen Gas Evolution Time Period
Popis výsledku anglicky
Presented paper studies corrosion kinetics of zinc dust in cement paste using acoustic emission and impedance spectroscopy (measurement of electric resistance of compact samples) method. The focus is on determination of hydrogen evolution period and its effect on porous structure of cement paste. Results more or less confirm results of other authors that the corrosion products of zinc are unable to efficiently fill the pores forming due to hydrogen. Time period of hydrogen evolution - cathodic corrosion reaction of zinc in alkaline environment of cement paste can be up to several days long. Keywords: hot-dip galvanized reinforcement, corrosion of zinc dust, acoustic emission method, hydrogen evolution, porosity of cement paste, electrochemical impedance spectroscopy
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-24234S" target="_blank" >GA20-24234S: Nová generace ekologických protikorozních povlaků konvenční výztuže betonu na bázi funkčních nanodisperzních organosilanů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Materials and Technologies of Modern Production
ISBN
978-3-0364-1168-2
Počet stran výsledku
6
Strana od-do
205-210
Počet stran knihy
274
Název nakladatele
Trans Tech Publications Ltd.
Místo vydání
Pfaffikon
Kód UT WoS kapitoly
—