Corrosion Properties and Bond Strength of Coated (PE/PAK; PE/PPE; PAD) Reinforcement (B500B) with Normal Strength Concrete
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F22%3A00363349" target="_blank" >RIV/68407700:21610/22:00363349 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.4028/p-z8sla8" target="_blank" >https://doi.org/10.4028/p-z8sla8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/p-z8sla8" target="_blank" >10.4028/p-z8sla8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Corrosion Properties and Bond Strength of Coated (PE/PAK; PE/PPE; PAD) Reinforcement (B500B) with Normal Strength Concrete
Popis výsledku v původním jazyce
The paper verifies anti-corrosion barrier protective properties of PE/PAK (polyethylene/polyacrylate), PE/PPE (polyethylene/polyproplylene) and PAD (polyamide) coatings of specific thickness on the surface of conventional ribbed bar B500B. Using pull-out test, the bond strength of such system was compared with bond strength of normal strength concrete (C30/37). Results of these tests show that key properties of coated systems are comparable to the previously tested epoxy coatings in case of their use in technical practice (protection of conventional rebar). In conclusion, their effective protective effect corresponds to minimal thickness higher than 300 µm but simultaneously lower the bond strength between the ribbed rebar and concrete.
Název v anglickém jazyce
Corrosion Properties and Bond Strength of Coated (PE/PAK; PE/PPE; PAD) Reinforcement (B500B) with Normal Strength Concrete
Popis výsledku anglicky
The paper verifies anti-corrosion barrier protective properties of PE/PAK (polyethylene/polyacrylate), PE/PPE (polyethylene/polyproplylene) and PAD (polyamide) coatings of specific thickness on the surface of conventional ribbed bar B500B. Using pull-out test, the bond strength of such system was compared with bond strength of normal strength concrete (C30/37). Results of these tests show that key properties of coated systems are comparable to the previously tested epoxy coatings in case of their use in technical practice (protection of conventional rebar). In conclusion, their effective protective effect corresponds to minimal thickness higher than 300 µm but simultaneously lower the bond strength between the ribbed rebar and concrete.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-24234S" target="_blank" >GA20-24234S: Nová generace ekologických protikorozních povlaků konvenční výztuže betonu na bázi funkčních nanodisperzních organosilanů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Materials and Technologies of Modern Production
ISBN
978-3-0364-1168-2
Počet stran výsledku
6
Strana od-do
185-190
Počet stran knihy
274
Název nakladatele
Trans Tech Publications Ltd.
Místo vydání
Pfaffikon
Kód UT WoS kapitoly
—