Effects of Hydrogen Embrittlement on the Structure and Strength of Prestressing Reinforcement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F25%3A00385865" target="_blank" >RIV/68407700:21610/25:00385865 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.2749/tokyo.2025.2027" target="_blank" >https://doi.org/10.2749/tokyo.2025.2027</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2749/tokyo.2025.2027" target="_blank" >10.2749/tokyo.2025.2027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of Hydrogen Embrittlement on the Structure and Strength of Prestressing Reinforcement
Popis výsledku v původním jazyce
The paper focuses on studying the influence of hydrogen on the mechanical properties of prestressing reinforcement in bridge structures. An experimental system was developed in which gaseous hydrogen is produced on the surface of steel in an exposure aqueous solution due to cathodic polarization (application of a direct current source). This hydrogen diffuses into the structure of the steel reinforcement. The influence of hydrogen on the reduction of mechanical properties (yield strength, tensile strength, ductility) is subsequently evaluated through tensile testing during the exposition of prestressing reinforcement samples, metallography, and examination of fracture surfaces (fractography) after the tensile tests. The article includes evaluations of all the above-mentioned characteristics in several different groups according to the differences of exposure and subsequent tensile tests.
Název v anglickém jazyce
Effects of Hydrogen Embrittlement on the Structure and Strength of Prestressing Reinforcement
Popis výsledku anglicky
The paper focuses on studying the influence of hydrogen on the mechanical properties of prestressing reinforcement in bridge structures. An experimental system was developed in which gaseous hydrogen is produced on the surface of steel in an exposure aqueous solution due to cathodic polarization (application of a direct current source). This hydrogen diffuses into the structure of the steel reinforcement. The influence of hydrogen on the reduction of mechanical properties (yield strength, tensile strength, ductility) is subsequently evaluated through tensile testing during the exposition of prestressing reinforcement samples, metallography, and examination of fracture surfaces (fractography) after the tensile tests. The article includes evaluations of all the above-mentioned characteristics in several different groups according to the differences of exposure and subsequent tensile tests.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA24-12783S" target="_blank" >GA24-12783S: Studium mechanizmů a kinetiky vodíkového korozního poškození konvenční předpínací výztuže betonových mostních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IABSE Symposium Tokyo 2025 Environmentally Friendly Technologies and Structures: Focusing on Sustainable Approaches
ISBN
978-3-85748-206-9
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
2027-2033
Název nakladatele
International Association for Bridge and Structural Engineering (IABSE)
Místo vydání
Zurich
Místo konání akce
Tokyo
Datum konání akce
18. 5. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—