Condition Evaluation of Inspected Bridges Built of Prestressed Standardized Precast Girders I-73 After 40 Years of Use
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F25%3A00386034" target="_blank" >RIV/68407700:21610/25:00386034 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Condition Evaluation of Inspected Bridges Built of Prestressed Standardized Precast Girders I-73 After 40 Years of Use
Popis výsledku v původním jazyce
The article provides a summary of the inspection results for eight highway bridges, each featuring a superstructure made of prestressed precast girders. Standardized I-73 girders, designed for clear spans of 21 to 30 meters, have been used in bridge construction in the Czech Republic since around 1975. The inspection focused on verifying the corrosion of the prestressing reinforcement and the grouting of ducts. Additionally, the actual concrete strength class was compared to the design strength, and a visual inspection of both the exterior surface and the internal chambers of the girders was conducted using a videoscope (Olympus IPLEX NX) and a digital camera. The article concludes with an overview of the most common defects found.
Název v anglickém jazyce
Condition Evaluation of Inspected Bridges Built of Prestressed Standardized Precast Girders I-73 After 40 Years of Use
Popis výsledku anglicky
The article provides a summary of the inspection results for eight highway bridges, each featuring a superstructure made of prestressed precast girders. Standardized I-73 girders, designed for clear spans of 21 to 30 meters, have been used in bridge construction in the Czech Republic since around 1975. The inspection focused on verifying the corrosion of the prestressing reinforcement and the grouting of ducts. Additionally, the actual concrete strength class was compared to the design strength, and a visual inspection of both the exterior surface and the internal chambers of the girders was conducted using a videoscope (Olympus IPLEX NX) and a digital camera. The article concludes with an overview of the most common defects found.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA24-12783S" target="_blank" >GA24-12783S: Studium mechanizmů a kinetiky vodíkového korozního poškození konvenční předpínací výztuže betonových mostních konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
fib Conference on Capacity Assessment of Corroded Reinforced Concrete Structures: from Research to Daily Engineering Evaluation, CACRCS 2025
ISBN
978-2-940643-30-1
ISSN
2617-4820
e-ISSN
—
Počet stran výsledku
7
Strana od-do
509-515
Název nakladatele
fib. The International Federation for Structural Concrete
Místo vydání
Lausanne
Místo konání akce
Lecco
Datum konání akce
30. 6. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—