Vlastnosti neutronového pixelového detektoru založeného na systému Medipix-2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F04%3A10107942" target="_blank" >RIV/68407700:21670/04:10107942 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Properties of Neutron Pixel Detector Based on Medipix-2 Device
Popis výsledku v původním jazyce
The neutron transmission radiography can serve as complementary diagnostic method to the X-ray radiography. It can produce contrast images of materials, which are indistinguishable in X-ray images. The properties of the neutron pixel detector based on the single X-ray photon pixel detector device Medipix-1 were already published. Slow neutrons are captured and converted in a surface layer containing Li-6 to tritons and alpha particles which are subsequently detected by a silicon pixel detector. A Medipix-2 detector (256 x 256 square pixels with pitch of 55 m) was adapted similarly. The detector performance was tested at the NEUTRA station of the Paul Scherrer Institute. The spatial resolution, detection efficiency and other detector propertieswere determined and compared with several types of contemporary neutron imaging systems. The results demonstrate superior state of the Medipix-2 based neutron imager in terms of the spatial resolution, linearity and dynamic range.
Název v anglickém jazyce
Properties of Neutron Pixel Detector Based on Medipix-2 Device
Popis výsledku anglicky
The neutron transmission radiography can serve as complementary diagnostic method to the X-ray radiography. It can produce contrast images of materials, which are indistinguishable in X-ray images. The properties of the neutron pixel detector based on the single X-ray photon pixel detector device Medipix-1 were already published. Slow neutrons are captured and converted in a surface layer containing Li-6 to tritons and alpha particles which are subsequently detected by a silicon pixel detector. A Medipix-2 detector (256 x 256 square pixels with pitch of 55 m) was adapted similarly. The detector performance was tested at the NEUTRA station of the Paul Scherrer Institute. The spatial resolution, detection efficiency and other detector propertieswere determined and compared with several types of contemporary neutron imaging systems. The results demonstrate superior state of the Medipix-2 based neutron imager in terms of the spatial resolution, linearity and dynamic range.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1P04LA211" target="_blank" >1P04LA211: Spolupráce ČR s CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Roma
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
???