Neutronová radiografie s izotropním osvětlením difúzním zdrojem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F05%3A15118128" target="_blank" >RIV/68407700:21670/05:15118128 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron Radiography with Isotropic Illumination by Diffuse Source
Popis výsledku v původním jazyce
The idea of the article is to use an isotropic illumination of a sample by thermal neutrons instead of a collimated beam for imaging purposes. The inspected object is placed to an isotropic field of slow neutrons and observed by a pinhole camera with animaging neutron detector. A fraction of neutrons scattered inside of the inspected sample can pass through the pinhole and reach the detector. The regions with larger cross-section for neutron scattering are highlighted in the acquired images. A compactexperimental system has been designed. The system consists of a semiconductor pixel detector Medipix2 (14 x 14 mm, 256 x 256 pixels) adapted for neutron detection, a pinhole collimator and a sample holder. The entire system is placed inside a waterproofbox. The neutron shielding was optimized using Monte-Carlo simulations. The first experimental results measured in the active zone of the research nuclear reactor LR-0 at Nuclear Research Institute in Rez near Prague are presented.
Název v anglickém jazyce
Neutron Radiography with Isotropic Illumination by Diffuse Source
Popis výsledku anglicky
The idea of the article is to use an isotropic illumination of a sample by thermal neutrons instead of a collimated beam for imaging purposes. The inspected object is placed to an isotropic field of slow neutrons and observed by a pinhole camera with animaging neutron detector. A fraction of neutrons scattered inside of the inspected sample can pass through the pinhole and reach the detector. The regions with larger cross-section for neutron scattering are highlighted in the acquired images. A compactexperimental system has been designed. The system consists of a semiconductor pixel detector Medipix2 (14 x 14 mm, 256 x 256 pixels) adapted for neutron detection, a pinhole collimator and a sample holder. The entire system is placed inside a waterproofbox. The neutron shielding was optimized using Monte-Carlo simulations. The first experimental results measured in the active zone of the research nuclear reactor LR-0 at Nuclear Research Institute in Rez near Prague are presented.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
0-7803-9222-1
Místo vydání
New Jersey
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno