USB Interface for Medipix2 Pixel Device Enabling Energy and Position Detection of Heavy Charged Particles
Popis výsledku v původním jazyce
We have designed an interface board between the Medipix2 single photon counting chip and USB (Universal Serial Bus), which is presently the most widespread PC interface. All necessary detector support is integrated into one compact system (80 x 50 x 20 mm3) including the detector bias source (up to 100 V). Power supply is internally derived from the voltage provided by the USB connection, so no external device is required. This solution allows to achieve maximum portability of the measurement setup. Oneof the most significant advantages is the support of back-side pulse processing. The charge generated by an ionizing particle is measured in the bias circuit and can be used for spectroscopic purposes or for triggering. With the present design the energy resolution of such spectrometry is about 44 keV. The interface board has been designed for connection with present chip boards carrying one or four Medipix2 chips.
Název v anglickém jazyce
USB Interface for Medipix2 Pixel Device Enabling Energy and Position Detection of Heavy Charged Particles
Popis výsledku anglicky
We have designed an interface board between the Medipix2 single photon counting chip and USB (Universal Serial Bus), which is presently the most widespread PC interface. All necessary detector support is integrated into one compact system (80 x 50 x 20 mm3) including the detector bias source (up to 100 V). Power supply is internally derived from the voltage provided by the USB connection, so no external device is required. This solution allows to achieve maximum portability of the measurement setup. Oneof the most significant advantages is the support of back-side pulse processing. The charge generated by an ionizing particle is measured in the bias circuit and can be used for spectroscopic purposes or for triggering. With the present design the energy resolution of such spectrometry is about 44 keV. The interface board has been designed for connection with present chip boards carrying one or four Medipix2 chips.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1P04LA211" target="_blank" >1P04LA211: Spolupráce ČR s CERN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
2006
Číslo periodika v rámci svazku
563
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
112-115
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—