Charakterizace plošné citlivosti 55 um pixelových detektorů na bázi CdTe pro rentgenové zobrazování
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F07%3A15142804" target="_blank" >RIV/68407700:21670/07:15142804 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of area sensitivity in 55 um pixellated CdTe X-ray imaging detectors
Popis výsledku v původním jazyce
X-ray imaging detectors with energy resolution, based on a single photon processing CMOS readout circuit attached to a detector chip, are being developed by different groups. In order to achieve high quantum efficiency it is preferable to use high-Z semiconductor materials. However the fluorescent X-ray photons of such materials have high energies and are able to travel long distances thereby reducing both the spatial resolution and the energy resolution of the detector. In addition charge sharing in the detector and non-uniformities in both the detector and the readout electronics will affect the signal. In this work we have characterized a 1 mm thick CdTe detector with a pixel size of 55 um x 55 um, bump bonded to the MEDIPIX2 single photon processing readout chip. The area sensitivity of the detector is evaluated using a narrow X-ray beam of monoenergetic photons. From these measurements the effects of fluorescence and charge sharing can be evaluated.
Název v anglickém jazyce
Characterization of area sensitivity in 55 um pixellated CdTe X-ray imaging detectors
Popis výsledku anglicky
X-ray imaging detectors with energy resolution, based on a single photon processing CMOS readout circuit attached to a detector chip, are being developed by different groups. In order to achieve high quantum efficiency it is preferable to use high-Z semiconductor materials. However the fluorescent X-ray photons of such materials have high energies and are able to travel long distances thereby reducing both the spatial resolution and the energy resolution of the detector. In addition charge sharing in the detector and non-uniformities in both the detector and the readout electronics will affect the signal. In this work we have characterized a 1 mm thick CdTe detector with a pixel size of 55 um x 55 um, bump bonded to the MEDIPIX2 single photon processing readout chip. The area sensitivity of the detector is evaluated using a narrow X-ray beam of monoenergetic photons. From these measurements the effects of fluorescence and charge sharing can be evaluated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2007 IEEE Nuclear Science Symposium & Medical Imaging Conference
ISBN
—
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Omipress
Místo vydání
Wisconsin
Místo konání akce
Hawai
Datum konání akce
27. 10. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—