Direct Observation of Decay of Radioactive Nuclei with Spatial and Time Coincidence Technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F11%3A00165656" target="_blank" >RIV/68407700:21670/11:00165656 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/journal/01689002" target="_blank" >http://www.sciencedirect.com/science/journal/01689002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.167" target="_blank" >10.1016/j.nima.2010.06.167</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Direct Observation of Decay of Radioactive Nuclei with Spatial and Time Coincidence Technique
Popis výsledku v původním jazyce
The position, energy and time sensitivity of the Timepix detector can be exploited for detection and spectroscopy of radioactive ions and their decay. The USB readout interface used for detector control and data acquisition can be adapted to receive an external clock and trigger from other detecting devices such as ionization chambers, scintillation and semiconductor detectors. Timepix can be thus used to (i) selectively detect chosen ions from a multiple-component ion beam, and (ii) record their subsequent decay. The high granularity of the pixel detector allows to apply not only temporal but also spatial coincidence technique for background suppression. This is particularly important for scarcely populated nuclei. Results are demonstrated by the measurement of 8He and 6He ions decay products and decay half-lives. Experiments were done on short-lived nuclei using radioactive ion beams of the Lohengrin fission fragment mass separator at the ILL Grenoble.
Název v anglickém jazyce
Direct Observation of Decay of Radioactive Nuclei with Spatial and Time Coincidence Technique
Popis výsledku anglicky
The position, energy and time sensitivity of the Timepix detector can be exploited for detection and spectroscopy of radioactive ions and their decay. The USB readout interface used for detector control and data acquisition can be adapted to receive an external clock and trigger from other detecting devices such as ionization chambers, scintillation and semiconductor detectors. Timepix can be thus used to (i) selectively detect chosen ions from a multiple-component ion beam, and (ii) record their subsequent decay. The high granularity of the pixel detector allows to apply not only temporal but also spatial coincidence technique for background suppression. This is particularly important for scarcely populated nuclei. Results are demonstrated by the measurement of 8He and 6He ions decay products and decay half-lives. Experiments were done on short-lived nuclei using radioactive ion beams of the Lohengrin fission fragment mass separator at the ILL Grenoble.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC07050" target="_blank" >LC07050: Centrum experimentální jaderné astrofyziky a jaderné fyziky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
633
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
3
Strana od-do
"S203"-"S205"
Kód UT WoS článku
000292782400061