Fast neutron detection efficiency of ATLAS-MPX detectors for the evaluation of average neutron energy in mixed radiation fields
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F11%3A00190733" target="_blank" >RIV/68407700:21670/11:00190733 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.174" target="_blank" >http://dx.doi.org/10.1016/j.nima.2010.06.174</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.174" target="_blank" >10.1016/j.nima.2010.06.174</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast neutron detection efficiency of ATLAS-MPX detectors for the evaluation of average neutron energy in mixed radiation fields
Popis výsledku v původním jazyce
Within the framework of the ATLAS-MPX project, the ATLAS-MPX detectors (based on Medipix2 silicon devices) are covered with converting layers of (6)LiF and polyethylene (PE) to make them sensitive to thermal and fast neutrons, respectively. Two ATLAS-MPXreference detectors were exposed to two calibrated neutron sources, (252)Cf (2.2 MeV mean neutron energy) and (241)AmBe (4.08 MeV mean neutron energy), in order to determine their fast neutron detection efficiency. Measurements were performed at low energy threshold (similar to 8 keV) and high energy threshold (similar to 230 keV). Fast neutron detection efficiency is primarily achieved via the use of a 1.3 mm thick polyethylene (PE) converter. Recoil protons from the elastic collision between neutronand hydrogen are detected from their tracks in the 300 mu m thick silicon pixel detector. Calibrated neutron sources were placed at different distances from the detectors, both separately and simultaneously in order to obtain single and s
Název v anglickém jazyce
Fast neutron detection efficiency of ATLAS-MPX detectors for the evaluation of average neutron energy in mixed radiation fields
Popis výsledku anglicky
Within the framework of the ATLAS-MPX project, the ATLAS-MPX detectors (based on Medipix2 silicon devices) are covered with converting layers of (6)LiF and polyethylene (PE) to make them sensitive to thermal and fast neutrons, respectively. Two ATLAS-MPXreference detectors were exposed to two calibrated neutron sources, (252)Cf (2.2 MeV mean neutron energy) and (241)AmBe (4.08 MeV mean neutron energy), in order to determine their fast neutron detection efficiency. Measurements were performed at low energy threshold (similar to 8 keV) and high energy threshold (similar to 230 keV). Fast neutron detection efficiency is primarily achieved via the use of a 1.3 mm thick polyethylene (PE) converter. Recoil protons from the elastic collision between neutronand hydrogen are detected from their tracks in the 300 mu m thick silicon pixel detector. Calibrated neutron sources were placed at different distances from the detectors, both separately and simultaneously in order to obtain single and s
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
633
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
"S226"-"S230"
Kód UT WoS článku
000292782400068