Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F11%3A00191679" target="_blank" >RIV/68407700:21670/11:00191679 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.164" target="_blank" >http://dx.doi.org/10.1016/j.nima.2010.06.164</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.164" target="_blank" >10.1016/j.nima.2010.06.164</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)
Popis výsledku v původním jazyce
Exposures were made with Medipix2 TimePix-based Si detectors at the HIMAC facility in Japan to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken at 15 degreesincrements for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. Estimates for the angular resolution for these types of tracks are also possible from these data, which are essential in the development of a TimePix-based dosimetric device for use in a space radiation environment. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si. Analysis of the images obtained shows t
Název v anglickém jazyce
Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)
Popis výsledku anglicky
Exposures were made with Medipix2 TimePix-based Si detectors at the HIMAC facility in Japan to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken at 15 degreesincrements for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. Estimates for the angular resolution for these types of tracks are also possible from these data, which are essential in the development of a TimePix-based dosimetric device for use in a space radiation environment. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si. Analysis of the images obtained shows t
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
633
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
190-193
Kód UT WoS článku
000292782400058
EID výsledku v databázi Scopus
—