Proton beam characterisation of a prototype thin-tile plastic scintillator detector with SiPM readout for use in fast-neutron tracker
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F12%3A00217191" target="_blank" >RIV/68407700:21670/12:00217191 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1748-0221/7/02/P02007" target="_blank" >http://dx.doi.org/10.1088/1748-0221/7/02/P02007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/7/02/P02007" target="_blank" >10.1088/1748-0221/7/02/P02007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Proton beam characterisation of a prototype thin-tile plastic scintillator detector with SiPM readout for use in fast-neutron tracker
Popis výsledku v původním jazyce
We present details of the construction and characterisation of a prototype thin-tile plastic scintillation detector for use in a multi-layer Fast Neutron Tracker. Scintillation light is read out using solid-state silicon photomultiplier detectors (SiPMs). The Tracker consists of alternating scintillator and Timepix detector layers. The scintillator tile provides a hydrogen-rich target, in which impinging fast neutrons produce recoil protons. The energies lost by protons in the plastic scintillator are measured and recoil protons exiting the scintillator are tracked in the Timepix detector. The combination of signals from the scintillator and Timepix provides information to reconstruct the energy or direction of the impinging neutron, using calculationsbased on the kinematics of the elastic neutron scattering. Three prototype scintillation detectors were constructed, using either a pair of 3 x 3 mm sensitive area SPMMicro3035 SiPMs from SensL or a pair of MAPD-3n SiPMs from Zecotek. Th
Název v anglickém jazyce
Proton beam characterisation of a prototype thin-tile plastic scintillator detector with SiPM readout for use in fast-neutron tracker
Popis výsledku anglicky
We present details of the construction and characterisation of a prototype thin-tile plastic scintillation detector for use in a multi-layer Fast Neutron Tracker. Scintillation light is read out using solid-state silicon photomultiplier detectors (SiPMs). The Tracker consists of alternating scintillator and Timepix detector layers. The scintillator tile provides a hydrogen-rich target, in which impinging fast neutrons produce recoil protons. The energies lost by protons in the plastic scintillator are measured and recoil protons exiting the scintillator are tracked in the Timepix detector. The combination of signals from the scintillator and Timepix provides information to reconstruct the energy or direction of the impinging neutron, using calculationsbased on the kinematics of the elastic neutron scattering. Three prototype scintillation detectors were constructed, using either a pair of 3 x 3 mm sensitive area SPMMicro3035 SiPMs from SensL or a pair of MAPD-3n SiPMs from Zecotek. Th
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010164" target="_blank" >TA01010164: Pokročilé techniky detekce ionizujícího záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
14
Strana od-do
—
Kód UT WoS článku
000303940900073
EID výsledku v databázi Scopus
—