Analysis of the Radiation Field in ATLAS Using 2008 2011 Data from the ATLAS-MPX Network
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F13%3A00217300" target="_blank" >RIV/68407700:21670/13:00217300 - isvavai.cz</a>
Výsledek na webu
<a href="http://cds.cern.ch/record/1544435#" target="_blank" >http://cds.cern.ch/record/1544435#</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of the Radiation Field in ATLAS Using 2008 2011 Data from the ATLAS-MPX Network
Popis výsledku v původním jazyce
The ATLAS-MPX collaboration has installed a network of 16 Medipix2 pixel detector based, single-quantum-sensitive devices before the LHC start-up in 2008 at various positions in the ATLAS experimental and technical caverns. The aim of the network is to perform real-time measurements of spectral characteristics and composition of the radiation environment inside the ATLAS detector during its operation and in particular already in the early stages with low luminosity. The detectors are generally sensitiveto all radiation species capable to deposit energy of at least 8 keV per single pixel. With the devices, in two different modes of operation, a large dynamic range of particle flux can be covered, of at least 9 orders of magnitude, which corresponds tothe highest luminosity, while also background measurement can be made.
Název v anglickém jazyce
Analysis of the Radiation Field in ATLAS Using 2008 2011 Data from the ATLAS-MPX Network
Popis výsledku anglicky
The ATLAS-MPX collaboration has installed a network of 16 Medipix2 pixel detector based, single-quantum-sensitive devices before the LHC start-up in 2008 at various positions in the ATLAS experimental and technical caverns. The aim of the network is to perform real-time measurements of spectral characteristics and composition of the radiation environment inside the ATLAS detector during its operation and in particular already in the early stages with low luminosity. The detectors are generally sensitiveto all radiation species capable to deposit energy of at least 8 keV per single pixel. With the devices, in two different modes of operation, a large dynamic range of particle flux can be covered, of at least 9 orders of magnitude, which corresponds tothe highest luminosity, while also background measurement can be made.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7E08050" target="_blank" >7E08050: Preparatory Phase of the Large Hadron Collider Upgrade</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Počet stran výsledku
94
Místo vydání
—
Název nakladatele resp. objednatele
CERN
Verze
—