Measurement of the radon diffusion through a nylon foil for different air humidities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F15%3A00234335" target="_blank" >RIV/68407700:21670/15:00234335 - isvavai.cz</a>
Výsledek na webu
<a href="http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4928023" target="_blank" >http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4928023</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4928023" target="_blank" >10.1063/1.4928023</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of the radon diffusion through a nylon foil for different air humidities
Popis výsledku v původním jazyce
The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained resultsof this study with a nylon foil with the thickness of 50 ?m are presented.
Název v anglickém jazyce
Measurement of the radon diffusion through a nylon foil for different air humidities
Popis výsledku anglicky
The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained resultsof this study with a nylon foil with the thickness of 50 ?m are presented.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Low Radioactivity Techniques 2015 (LRT 2015): Proceedings of the 5th International Workshop in Low Radioactivity Techniques
ISBN
978-0-7354-1319-1
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"140007-1"-"140007-4"
Název nakladatele
AIP Conference Proceedings
Místo vydání
New York
Místo konání akce
Seattle, WA
Datum konání akce
18. 3. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000371688900046