Pixelman for Neutron Radiography Detectors (Widepix 4x5 and Mutipix system)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F15%3A00234686" target="_blank" >RIV/68407700:21670/15:00234686 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.utef.cvut.cz/products" target="_blank" >http://www.utef.cvut.cz/products</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pixelman for Neutron Radiography Detectors (Widepix 4x5 and Mutipix system)
Popis výsledku v původním jazyce
Software is used for operation of the newly developer detector Widepix 4x5 and for the modular detector system Multipix. Both detecting devices were developed for the newly build thermal neutron imaging beamlines at Rez near Prague (LVR-15 fission reactor source). Both detectors are based on the so-called semiconductor hybrid pixel detector technology (Timepix chips used). Software enables controlling detectors (detector communication, data read-out, data visualization, application of various correction filters, ...) as well as remote operation of all positioning stages in the respective imaging stations. Thanks to the included scripting tool, software enables operation of very complex multi-parametric measurements (such as acquiring of computed tomography scans). Thanks to open architecture in which individual modalities are implemented in a form of plugins, further software extension (implementation of new detectors, further motor stages etc.) is possible. Software can be operated under Windows, Mac OS and Linux.
Název v anglickém jazyce
Pixelman for Neutron Radiography Detectors (Widepix 4x5 and Mutipix system)
Popis výsledku anglicky
Software is used for operation of the newly developer detector Widepix 4x5 and for the modular detector system Multipix. Both detecting devices were developed for the newly build thermal neutron imaging beamlines at Rez near Prague (LVR-15 fission reactor source). Both detectors are based on the so-called semiconductor hybrid pixel detector technology (Timepix chips used). Software enables controlling detectors (detector communication, data read-out, data visualization, application of various correction filters, ...) as well as remote operation of all positioning stages in the respective imaging stations. Thanks to the included scripting tool, software enables operation of very complex multi-parametric measurements (such as acquiring of computed tomography scans). Thanks to open architecture in which individual modalities are implemented in a form of plugins, further software extension (implementation of new detectors, further motor stages etc.) is possible. Software can be operated under Windows, Mac OS and Linux.
Klasifikace
Druh
R - Software
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010237" target="_blank" >TA01010237: Pracoviště pro nedestruktivní testování, diagnostiku a 3D zobrazování pomocí neutronové radiografie a tomografie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
Pixelman for netron raidography
Technické parametry
Ústav technické a experimentální fyziky
Ekonomické parametry
Dodává se spolu s HW, jenož cena je závislá na počtu instalovných čipů (typycky 3-6 tis. EUR pro jednočipové zařízení v závislosit na komlexnosti vyčítacího HW)
IČO vlastníka výsledku
68407700
Název vlastníka
35000