Imaging performance of a Timepix detector based on semi-insulating GaAs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F18%3A00319854" target="_blank" >RIV/68407700:21670/18:00319854 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01034/" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01034/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/13/01/C01034" target="_blank" >10.1088/1748-0221/13/01/C01034</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Imaging performance of a Timepix detector based on semi-insulating GaAs
Popis výsledku v původním jazyce
This work focused on a Timepix chip [1] coupled with a bulk semi-insulating GaAs sensor. The sensor consisted of a matrix of 256 x 256 pixels with a pitch of 55 mu m bump-bonded to a Timepix ASIC. The sensor was processed on a 350 mu m-thick SI GaAs wafer. We carried out detector adjustment to optimize its performance. This included threshold equalization with setting up parameters of the Timepix chip, such as Ikrum, Pream, Vfbk, and so on. The energy calibration of the GaAs Timepix detector was realized using a Am-241 radioisotope in two Timepix detector modes: time-over-threshold and threshold scan. An energy resolution of 4.4 keV in FWHM (Full Width at Half Maximum) was observed for 59.5 keV gamma-photons using threshold scan mode. The X-ray imaging quality of the GaAs Timepix detector was tested using various samples irradiated by an X-ray source with a focal spot size smaller than 8 gamma m and accelerating voltage up to 80 kV. A 700 gamma m x 700 mu m gold testing object (X-500-200-16Au with Siemens star) fabricated with high precision was used for the spatial resolution testing at different values of X-ray image magnification (up to 45). The measured spatial resolution of our X-ray imaging system was about 4 mu m.
Název v anglickém jazyce
Imaging performance of a Timepix detector based on semi-insulating GaAs
Popis výsledku anglicky
This work focused on a Timepix chip [1] coupled with a bulk semi-insulating GaAs sensor. The sensor consisted of a matrix of 256 x 256 pixels with a pitch of 55 mu m bump-bonded to a Timepix ASIC. The sensor was processed on a 350 mu m-thick SI GaAs wafer. We carried out detector adjustment to optimize its performance. This included threshold equalization with setting up parameters of the Timepix chip, such as Ikrum, Pream, Vfbk, and so on. The energy calibration of the GaAs Timepix detector was realized using a Am-241 radioisotope in two Timepix detector modes: time-over-threshold and threshold scan. An energy resolution of 4.4 keV in FWHM (Full Width at Half Maximum) was observed for 59.5 keV gamma-photons using threshold scan mode. The X-ray imaging quality of the GaAs Timepix detector was tested using various samples irradiated by an X-ray source with a focal spot size smaller than 8 gamma m and accelerating voltage up to 80 kV. A 700 gamma m x 700 mu m gold testing object (X-500-200-16Au with Siemens star) fabricated with high precision was used for the spatial resolution testing at different values of X-ray image magnification (up to 45). The measured spatial resolution of our X-ray imaging system was about 4 mu m.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10300 - Physical sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_013%2F0001785" target="_blank" >EF16_013/0001785: Urychlovač Van de Graaff - laditelný zdroj monoenergetických neutronů a lehkých iontů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
13
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000423302400009
EID výsledku v databázi Scopus
2-s2.0-85041830406