Medipix detectors in radiation therapy for advanced quality-assurance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F20%3A00347561" target="_blank" >RIV/68407700:21670/20:00347561 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.radmeas.2019.106211" target="_blank" >https://doi.org/10.1016/j.radmeas.2019.106211</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2019.106211" target="_blank" >10.1016/j.radmeas.2019.106211</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Medipix detectors in radiation therapy for advanced quality-assurance
Popis výsledku v původním jazyce
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in real-time. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.
Název v anglickém jazyce
Medipix detectors in radiation therapy for advanced quality-assurance
Popis výsledku anglicky
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in real-time. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30500 - Other medical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
130
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
18
Strana od-do
—
Kód UT WoS článku
000514012300009
EID výsledku v databázi Scopus
2-s2.0-85075551706