Influence of the Geometric Arrangement of the Active Ceiling Soffit on Its Overall Cooling Performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F18%3A00322558" target="_blank" >RIV/68407700:21720/18:00322558 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of the Geometric Arrangement of the Active Ceiling Soffit on Its Overall Cooling Performance
Popis výsledku v původním jazyce
This paper focuses on active ceiling soffits which provide heating and cooling especially in office buildings. A particular disadvantage of these systems is their low performance, when they work in cooling mode. These soffits are often installed all over the ceiling area which creates aclosed cavity behind them. The cooling capacity can be increased by partially cutting thesoffit and opening the cavity. This soffit adjustment results in natural flow around its structure and increasescooling capacity of the soffit. This paper is dedicated to the suspended ceiling geometry effect on its cooling performance. Cooling performance of individual geometric arrangements is evaluated usingCFD simulations. These simulations are also complemented by measurements on a real soffit installed in the laboratory of the university's research centre in its climate chamber.
Název v anglickém jazyce
Influence of the Geometric Arrangement of the Active Ceiling Soffit on Its Overall Cooling Performance
Popis výsledku anglicky
This paper focuses on active ceiling soffits which provide heating and cooling especially in office buildings. A particular disadvantage of these systems is their low performance, when they work in cooling mode. These soffits are often installed all over the ceiling area which creates aclosed cavity behind them. The cooling capacity can be increased by partially cutting thesoffit and opening the cavity. This soffit adjustment results in natural flow around its structure and increasescooling capacity of the soffit. This paper is dedicated to the suspended ceiling geometry effect on its cooling performance. Cooling performance of individual geometric arrangements is evaluated usingCFD simulations. These simulations are also complemented by measurements on a real soffit installed in the laboratory of the university's research centre in its climate chamber.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 9th Asian Conference on Refrigeration and Air-conditioning
ISBN
978-4-88967-138-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Japan Society of Refrigerating and Air Conditioning Engineers
Místo vydání
Tokyo
Místo konání akce
Sapporo
Datum konání akce
10. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—