Roof Windows for Passive Houses – What Can Be Improved?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F18%3A00328774" target="_blank" >RIV/68407700:21720/18:00328774 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Roof Windows for Passive Houses – What Can Be Improved?
Popis výsledku v původním jazyce
In general, skylights and roof windows in pitched roofs can be described as the critical components of buildings concerning heat losses, risk of surface condensation, increased risk of overheating of rooms behind etc. This is very sensible task especially for passive house solutions. The paper informs about studies analyzing the importance of these relatively small areas in the building envelope and more detailed in pitched roof of a passive house. One of the key problems is the position of roof window within the pitched roof construction. Second part of the paper comments results of detailed analysis of thermal performance for different combination of frame type and glazing. These studies are performed hand in hand with development works. It is documented that such approach can lead to promising results, reducing the thermal transmittance of roof window to 0.7 – 0.5 W/(m2K). If we consider the real roof window quality including the thermal couplings due to window installation such thermal transmittance stays safely bellow 0.9 W/(m2K).
Název v anglickém jazyce
Roof Windows for Passive Houses – What Can Be Improved?
Popis výsledku anglicky
In general, skylights and roof windows in pitched roofs can be described as the critical components of buildings concerning heat losses, risk of surface condensation, increased risk of overheating of rooms behind etc. This is very sensible task especially for passive house solutions. The paper informs about studies analyzing the importance of these relatively small areas in the building envelope and more detailed in pitched roof of a passive house. One of the key problems is the position of roof window within the pitched roof construction. Second part of the paper comments results of detailed analysis of thermal performance for different combination of frame type and glazing. These studies are performed hand in hand with development works. It is documented that such approach can lead to promising results, reducing the thermal transmittance of roof window to 0.7 – 0.5 W/(m2K). If we consider the real roof window quality including the thermal couplings due to window installation such thermal transmittance stays safely bellow 0.9 W/(m2K).
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TH01021120" target="_blank" >TH01021120: Střešní okna nové generace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů