Optimization Method for Photovoltaic Integration in Residential Houses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F19%3A00337404" target="_blank" >RIV/68407700:21720/19:00337404 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1742-6596/1343/1/012093" target="_blank" >https://iopscience.iop.org/article/10.1088/1742-6596/1343/1/012093</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/1343/1/012093" target="_blank" >10.1088/1742-6596/1343/1/012093</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimization Method for Photovoltaic Integration in Residential Houses
Popis výsledku v původním jazyce
Good design and sizing of photovoltaic (PV) systems is very important in order to effectively harvest energy and minimize the investment cost. The optimum tilt and azimuth angles at which a PV system should be installed are often debated. This paper evaluates the trade-off between annual energy generation and payback period reduction through the analysis of a small house with pitched roof integrated PVs in both East and West sides. Validated irradiance and PV models were used for the analysis. The optimum tilt and azimuth angles are found to be 35° and 10° respectively. Finally, a contour map plot illustrating all possible tilt and orientation angles, corresponding to a payback period less than 20 years, is provided. The results are valid for different building typologies and locations with similar climate conditions as Prague.
Název v anglickém jazyce
Optimization Method for Photovoltaic Integration in Residential Houses
Popis výsledku anglicky
Good design and sizing of photovoltaic (PV) systems is very important in order to effectively harvest energy and minimize the investment cost. The optimum tilt and azimuth angles at which a PV system should be installed are often debated. This paper evaluates the trade-off between annual energy generation and payback period reduction through the analysis of a small house with pitched roof integrated PVs in both East and West sides. Validated irradiance and PV models were used for the analysis. The optimum tilt and azimuth angles are found to be 35° and 10° respectively. Finally, a contour map plot illustrating all possible tilt and orientation angles, corresponding to a payback period less than 20 years, is provided. The results are valid for different building typologies and locations with similar climate conditions as Prague.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CISBAT 2019 Proceedings
ISBN
—
ISSN
1742-6588
e-ISSN
1742-6596
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institute of Physics Publishing
Místo vydání
Bristol
Místo konání akce
Lausanne
Datum konání akce
4. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000561852800093