Design and Monitoring of Energy-Active Facade Module
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F20%3A00342019" target="_blank" >RIV/68407700:21720/20:00342019 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1051/e3sconf/202017224005" target="_blank" >https://doi.org/10.1051/e3sconf/202017224005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/e3sconf/202017224005" target="_blank" >10.1051/e3sconf/202017224005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and Monitoring of Energy-Active Facade Module
Popis výsledku v původním jazyce
Testing of two facade modules under outdoor climatic conditions of Central Europe has been performed for more than two years. The paper analyses the results of long-term monitoring and shows potential benefits of prismatic glazing and photovoltaic-thermal (PVT) collectors integrated into one component. The prismatic glazing reflects beam radiation during summer period and transmits it during the winter period. During summer month solar irradiation transmitted through the prismatic glazing can be about 44 % lower compared to conventional triple glazing. Glazed PVT collector generates heat and electricity simultaneously. PVT collector integrated in the façade module can achieve solar yield during summer 58 kWh/m2.month in heat and 6,3 kWh/m2.month in electricity.
Název v anglickém jazyce
Design and Monitoring of Energy-Active Facade Module
Popis výsledku anglicky
Testing of two facade modules under outdoor climatic conditions of Central Europe has been performed for more than two years. The paper analyses the results of long-term monitoring and shows potential benefits of prismatic glazing and photovoltaic-thermal (PVT) collectors integrated into one component. The prismatic glazing reflects beam radiation during summer period and transmits it during the winter period. During summer month solar irradiation transmitted through the prismatic glazing can be about 44 % lower compared to conventional triple glazing. Glazed PVT collector generates heat and electricity simultaneously. PVT collector integrated in the façade module can achieve solar yield during summer 58 kWh/m2.month in heat and 6,3 kWh/m2.month in electricity.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1605" target="_blank" >LO1605: Univerzitní centrum energeticky efektivních budov – Fáze udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
E3S Web of Conferences Volume 172 (2020) - 12th Nordic Symposium on Building Physics (NSB 2020)
ISBN
—
ISSN
2555-0403
e-ISSN
2267-1242
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis Cedex A
Místo konání akce
Tallinn
Datum konání akce
7. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000594033400238