A New Approach to a Local Residential Ventilation Unit Regarding to Supply Air Temperature
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F21%3A00352311" target="_blank" >RIV/68407700:21720/21:00352311 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A New Approach to a Local Residential Ventilation Unit Regarding to Supply Air Temperature
Popis výsledku v původním jazyce
The paper presents a technical solution of an advanced local ventilation unit that uses a heat exchanger with thermoelectric modules to adjust the temperature of fresh air. Together with regular heat-recovery heat exchanger the unit provides capacity for air cooling and heating without any additional support of building heating and cooling systems. The benefits of the solution are supported by the results of laboratory measurements. At this point the range of heating output of entire ventilation unit has been measured between 300 to 700 W at supply airflow rate 50 m3/h and COP 2.5 to 20. While the range of cooling output is between 100 to 200 W at the same airflow rate and EER of the unit is from 1 to 5. The paper presents feasibility of the novel solution despite low efficiency of thermoelectric modules. It also describes a specific behaviour of an exchanger with thermoelectric modules, where requirements for control are pointed out.
Název v anglickém jazyce
A New Approach to a Local Residential Ventilation Unit Regarding to Supply Air Temperature
Popis výsledku anglicky
The paper presents a technical solution of an advanced local ventilation unit that uses a heat exchanger with thermoelectric modules to adjust the temperature of fresh air. Together with regular heat-recovery heat exchanger the unit provides capacity for air cooling and heating without any additional support of building heating and cooling systems. The benefits of the solution are supported by the results of laboratory measurements. At this point the range of heating output of entire ventilation unit has been measured between 300 to 700 W at supply airflow rate 50 m3/h and COP 2.5 to 20. While the range of cooling output is between 100 to 200 W at the same airflow rate and EER of the unit is from 1 to 5. The paper presents feasibility of the novel solution despite low efficiency of thermoelectric modules. It also describes a specific behaviour of an exchanger with thermoelectric modules, where requirements for control are pointed out.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TK01020180" target="_blank" >TK01020180: Inovativní větrací jednotka s termoelektrickými moduly pro řízení teploty vzduchu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings Book of the Roomvent Conference 2020
ISBN
9788894612301
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
CCI Centro Congressi Internazionale s.r.l.
Místo vydání
Turin
Místo konání akce
online
Datum konání akce
15. 2. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce