Measurements of water vapour permeability of oriented strand boards
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F22%3A00360452" target="_blank" >RIV/68407700:21720/22:00360452 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1742-6596/2341/1/012016" target="_blank" >https://doi.org/10.1088/1742-6596/2341/1/012016</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/2341/1/012016" target="_blank" >10.1088/1742-6596/2341/1/012016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurements of water vapour permeability of oriented strand boards
Popis výsledku v původním jazyce
Oriented strand boards (OSB) are one of the most used elements in modern timber-based buildings. An important property is their permeability to water vapour. It is commonly characterized by the diffusion resistance factor (μ-value). It is not a constant, but a moisture-dependent function that is most often determined using the cup method. However, results found in the literature have large variance. This paper presents the results of carefully performed laboratory measurements using the cup method. Measurements were made at different sorption moisture contents of OSB. The measured μ-values ranged from 40 for samples with high moisture content to 160 for samples with low moisture content. The measured values were used to derive moisture-dependent functions that cover the entire hygroscopic range. They can be used in hygrothermal modelling of building envelopes containing OSB.
Název v anglickém jazyce
Measurements of water vapour permeability of oriented strand boards
Popis výsledku anglicky
Oriented strand boards (OSB) are one of the most used elements in modern timber-based buildings. An important property is their permeability to water vapour. It is commonly characterized by the diffusion resistance factor (μ-value). It is not a constant, but a moisture-dependent function that is most often determined using the cup method. However, results found in the literature have large variance. This paper presents the results of carefully performed laboratory measurements using the cup method. Measurements were made at different sorption moisture contents of OSB. The measured μ-values ranged from 40 for samples with high moisture content to 160 for samples with low moisture content. The measured values were used to derive moisture-dependent functions that cover the entire hygroscopic range. They can be used in hygrothermal modelling of building envelopes containing OSB.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TN01000056" target="_blank" >TN01000056: Centrum pokročilých materiálů a efektivních budov</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Physics: Conference Series
ISBN
—
ISSN
1742-6588
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
IOP Publishing Ltd
Místo vydání
Bristol
Místo konání akce
Telč
Datum konání akce
6. 6. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—