Univariate Analysis of Prenatal Risk Factors for Low Umbilical Cord Artery pH at Birth
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21730%2F16%3A00303632" target="_blank" >RIV/68407700:21730/16:00303632 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/16:00303632
Výsledek na webu
<a href="https://www.springerprofessional.de/en/univariate-analysis-of-prenatal-risk-factors-for-low-umbilical-c/10561998" target="_blank" >https://www.springerprofessional.de/en/univariate-analysis-of-prenatal-risk-factors-for-low-umbilical-c/10561998</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-43949-5_14" target="_blank" >10.1007/978-3-319-43949-5_14</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Univariate Analysis of Prenatal Risk Factors for Low Umbilical Cord Artery pH at Birth
Popis výsledku v původním jazyce
Objective: To identify potential risk factors for low umbilical cord artery pH in term, singleton pregnancies. Methods: Retrospective case-control study. Cases were deliveries characterized by umbilical cord artery pH<=7.05. Controls were with no sign of hypoxia. Results: In the database of 10637 deliveries, collected between 2014 and 2015 at the University Hospital in Brno delivery ward, we identified 99 cases. Univariate analysis of clinical features was performed. The following risk-factors were associated with low pH: the length of the first stage (odds ratio (OR) 1.40 (95 % CI 1.04–1.89)) and the length of the second stage of labor (OR 2.86 (95 % CI 1.70–4.81)), primipara (OR 2.99 (1.90–4.71)) and meconium stained fluid (OR 1.60 (1.07–2.38)). Conclusion: Among the risk factors that increase the chance of low umbilical cord artery pH at term, we identified: excessive length of the first and second stage of labour, parity, and meconium stained fluid.
Název v anglickém jazyce
Univariate Analysis of Prenatal Risk Factors for Low Umbilical Cord Artery pH at Birth
Popis výsledku anglicky
Objective: To identify potential risk factors for low umbilical cord artery pH in term, singleton pregnancies. Methods: Retrospective case-control study. Cases were deliveries characterized by umbilical cord artery pH<=7.05. Controls were with no sign of hypoxia. Results: In the database of 10637 deliveries, collected between 2014 and 2015 at the University Hospital in Brno delivery ward, we identified 99 cases. Univariate analysis of clinical features was performed. The following risk-factors were associated with low pH: the length of the first stage (odds ratio (OR) 1.40 (95 % CI 1.04–1.89)) and the length of the second stage of labor (OR 2.86 (95 % CI 1.70–4.81)), primipara (OR 2.99 (1.90–4.71)) and meconium stained fluid (OR 1.60 (1.07–2.38)). Conclusion: Among the risk factors that increase the chance of low umbilical cord artery pH at term, we identified: excessive length of the first and second stage of labour, parity, and meconium stained fluid.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP14-28462P" target="_blank" >GP14-28462P: Statistické metody zpracování signálu KTG při porodu zasazené do kontextu klinických informací</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Information Technology in Bio- and Medical Informatics
ISBN
978-3-319-43948-8
ISSN
0302-9743
e-ISSN
—
Počet stran výsledku
6
Strana od-do
186-191
Název nakladatele
Springer
Místo vydání
Basel
Místo konání akce
Porto
Datum konání akce
5. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000389336800014