Search for sub-GeV dark matter via the Migdal effect with an EDELWEISS germanium detector with NbSi transition-edge sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90107%2F22%3A00363782" target="_blank" >RIV/68407700:90107/22:00363782 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1103/PhysRevD.106.062004" target="_blank" >https://doi.org/10.1103/PhysRevD.106.062004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1103/PhysRevD.106.062004" target="_blank" >10.1103/PhysRevD.106.062004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Search for sub-GeV dark matter via the Migdal effect with an EDELWEISS germanium detector with NbSi transition-edge sensors
Popis výsledku v původním jazyce
The EDELWEISS collaboration reports on the search for dark matter particle interactions via Migdal effect with masses between 32 MeV . c-2 to 2 GeV . c-2 using a 200 g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a transition edge sensor made of a NbSi thin film. The detector was biased at 66 V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of 4.46 eVee (102.58 eV at 66 V) and an analysis threshold of 30 eVee. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross sections down to 10-29 cm2 and masses between 32 and 100 MeV . c-2. The achieved low threshold with the NbSi sensor shows the relevance of its use for out-of-equilibrium phonon sensitive devices for low-mass dark matter searches.
Název v anglickém jazyce
Search for sub-GeV dark matter via the Migdal effect with an EDELWEISS germanium detector with NbSi transition-edge sensors
Popis výsledku anglicky
The EDELWEISS collaboration reports on the search for dark matter particle interactions via Migdal effect with masses between 32 MeV . c-2 to 2 GeV . c-2 using a 200 g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a transition edge sensor made of a NbSi thin film. The detector was biased at 66 V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of 4.46 eVee (102.58 eV at 66 V) and an analysis threshold of 30 eVee. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross sections down to 10-29 cm2 and masses between 32 and 100 MeV . c-2. The achieved low threshold with the NbSi sensor shows the relevance of its use for out-of-equilibrium phonon sensitive devices for low-mass dark matter searches.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physical Review D
ISSN
2470-0010
e-ISSN
2470-0029
Svazek periodika
106
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
"062004-1"-"062004-10"
Kód UT WoS článku
000916404500009
EID výsledku v databázi Scopus
2-s2.0-85139627301