Perspectives of a single-anode cylindrical chamber operating in ionization mode and high gas pressure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90263%2F24%3A00386597" target="_blank" >RIV/68407700:90263/24:00386597 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1140/epjc/s10052-024-12864-w" target="_blank" >https://doi.org/10.1140/epjc/s10052-024-12864-w</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1140/epjc/s10052-024-12864-w" target="_blank" >10.1140/epjc/s10052-024-12864-w</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Perspectives of a single-anode cylindrical chamber operating in ionization mode and high gas pressure
Popis výsledku v původním jazyce
As part of the R2D2 (Rare Decays with Radial Detector) R &D, the use of a gas detector with a spherical or cylindrical cathode, equipped with a single anode and operating at high pressure, was studied for the search of rare phenomena such as neutrinoless double-beta decay. The presented measurements were obtained with a cylindrical detector, covering gas pressures ranging from 1 to 10 bar in argon and 1 to 6 bar in xenon, using both a point-like source of 210Po (5.3 MeV α) and a diffuse source of 222Rn (5.5 MeV α). Analysis and interpretation of the data were developed using the anodic current waveform. Similar detection performances were achieved with both gases, and comparable energy resolutions were measured with both sources. As long as the purity of the gas was sufficient, no significant degradation of the measured energy was observed by increasing the pressure. At the highest operating pressure, an energy resolution better than 1.5% full-width at half-maximum (FWHM) was obtained for both gaseous media, although optimal noise conditions were not reached.
Název v anglickém jazyce
Perspectives of a single-anode cylindrical chamber operating in ionization mode and high gas pressure
Popis výsledku anglicky
As part of the R2D2 (Rare Decays with Radial Detector) R &D, the use of a gas detector with a spherical or cylindrical cathode, equipped with a single anode and operating at high pressure, was studied for the search of rare phenomena such as neutrinoless double-beta decay. The presented measurements were obtained with a cylindrical detector, covering gas pressures ranging from 1 to 10 bar in argon and 1 to 6 bar in xenon, using both a point-like source of 210Po (5.3 MeV α) and a diffuse source of 222Rn (5.5 MeV α). Analysis and interpretation of the data were developed using the anodic current waveform. Similar detection performances were achieved with both gases, and comparable energy resolutions were measured with both sources. As long as the purity of the gas was sufficient, no significant degradation of the measured energy was observed by increasing the pressure. At the highest operating pressure, an energy resolution better than 1.5% full-width at half-maximum (FWHM) was obtained for both gaseous media, although optimal noise conditions were not reached.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Physical Journal C
ISSN
1434-6044
e-ISSN
1434-6052
Svazek periodika
84
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
001227190500003
EID výsledku v databázi Scopus
2-s2.0-85193545258