Testing of non-destructive decontamination means: determination of decontamination efficacy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F12%3A%230000259" target="_blank" >RIV/70565813:_____/12:#0000259 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing of non-destructive decontamination means: determination of decontamination efficacy
Popis výsledku v původním jazyce
Testing of non-destructive decontamination means is carried out in toxicological chamber, a special plant designed for safe work with chemical warfare agents (CWA). Defined amount of small droplets of yperite (HD) is inserted on stainless steel testing targets. Thereafter, HD contaminated testing targets are placed in certain positions on surface of stainless steel table situated inside the toxicological chamber. Such arrangement simulates any complex enclosed room contaminated by aerosol of CWA. Decontamination means to be tested is used for decontamination then, i.e. aerosolised into toxicological chamber in desired form and quantity, whereas time required for decontamination reaction is measured. Finally, HD and its decomposition residues remainingon testing targets are extracted and analysed using GC-MS method. On the basis of HD concentration decrease, efficacy of tested decontamination means is calculated.
Název v anglickém jazyce
Testing of non-destructive decontamination means: determination of decontamination efficacy
Popis výsledku anglicky
Testing of non-destructive decontamination means is carried out in toxicological chamber, a special plant designed for safe work with chemical warfare agents (CWA). Defined amount of small droplets of yperite (HD) is inserted on stainless steel testing targets. Thereafter, HD contaminated testing targets are placed in certain positions on surface of stainless steel table situated inside the toxicological chamber. Such arrangement simulates any complex enclosed room contaminated by aerosol of CWA. Decontamination means to be tested is used for decontamination then, i.e. aerosolised into toxicological chamber in desired form and quantity, whereas time required for decontamination reaction is measured. Finally, HD and its decomposition residues remainingon testing targets are extracted and analysed using GC-MS method. On the basis of HD concentration decrease, efficacy of tested decontamination means is calculated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20112015013" target="_blank" >VF20112015013: Výzkum moderních metod detekce a identifikace nebezpečných CBRN látek a materiálů, metod snížení jejich nebezpečnosti a dekontaminace; výzkum moderních prostředků ochrany osob a prvků kritické infrastruktury</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Proceedings of IX. International Chemical and Biological Medical Treatment Symposium
ISSN
1092-7255
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
2012
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—