The Influence of the Equilibrium Factor on the Estimated Annual Effective Dose from Inhaled RnDP in Selected Workplaces
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F20%3AN0000027" target="_blank" >RIV/70565813:_____/20:N0000027 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article-abstract/191/2/188/5942911?redirectedFrom=PDF" target="_blank" >https://academic.oup.com/rpd/article-abstract/191/2/188/5942911?redirectedFrom=PDF</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncaa165" target="_blank" >10.1093/rpd/ncaa165</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Influence of the Equilibrium Factor on the Estimated Annual Effective Dose from Inhaled RnDP in Selected Workplaces
Popis výsledku v původním jazyce
Measurements of activity concentration of radon gas and radon decay products were carried out in several workplaces including schools, radium spas, swimming pools, water treatment plants, caves and former mines. Based on these measurements, annual effective doses to workers were estimated and values of the equilibrium factor, F, were calculated. This paper describes the different approaches used to estimate the annual effective dose based on the dose coefficients recommended by the International Commission on Radiological Protection. Using the measured F values as opposed to the default F value of 0.4 changed the doses by about 5–95% depending mainly upon the ventilation conditions of the workplace.
Název v anglickém jazyce
The Influence of the Equilibrium Factor on the Estimated Annual Effective Dose from Inhaled RnDP in Selected Workplaces
Popis výsledku anglicky
Measurements of activity concentration of radon gas and radon decay products were carried out in several workplaces including schools, radium spas, swimming pools, water treatment plants, caves and former mines. Based on these measurements, annual effective doses to workers were estimated and values of the equilibrium factor, F, were calculated. This paper describes the different approaches used to estimate the annual effective dose based on the dose coefficients recommended by the International Commission on Radiological Protection. Using the measured F values as opposed to the default F value of 0.4 changed the doses by about 5–95% depending mainly upon the ventilation conditions of the workplace.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/TITSSUJB702" target="_blank" >TITSSUJB702: Vliv koncentrace a velikostní distribuce aerosolových částic na poměr vázané a nevázané složky přeměnových produktů radonu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
191
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
188-191
Kód UT WoS článku
000606027000015
EID výsledku v databázi Scopus
2-s2.0-85097004339