International Intercomparison and Quality Assessment of Passive and Active 222Rn Measuring Devices in the Asia-Pacific Region
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F24%3AN0000008" target="_blank" >RIV/70565813:_____/24:N0000008 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1350448724002439#preview-section-snippets" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1350448724002439#preview-section-snippets</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2024.107295" target="_blank" >10.1016/j.radmeas.2024.107295</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
International Intercomparison and Quality Assessment of Passive and Active 222Rn Measuring Devices in the Asia-Pacific Region
Popis výsledku v původním jazyce
Intercomparison exercise is an integral part of the quality assurance programmes in 222Rn measurements using active and passive devices. Ensuring the accuracy of data generated through measurements necessitates periodic performance checks. To achieve harmonization of methods, quantify biases and errors in measurements, and identify the reasons for discrepancies, there is a pressing need for periodic intercomparison exercises. To address this need of numerous laboratories, particularly in the Asia-Pacific region, a calibration facility for 222Rn measuring devices has been established at the Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, India. An international intercomparison exercise for the 222Rn measuring devices was conducted at this facility in the year 2022 with the participation of 10 laboratories from six countries. A total of 354 devices (comprising of both active and passive detectors) were subjected to intercomparison measurements by exposing them to three concentration levels: (5.97 ± 0.29) × 103 Bq m−3, (0.70 ± 0.09) × 103 Bq m−3 and (2.02 ± 0.20) × 103 Bq m−3 in separate experiments and the exposure durations were 7 days, 15 days, and 10 days respectively. The performance of each laboratory was evaluated following the criterion adopted by the International Atomic Energy Agency (IAEA) in its worldwide proficiency test programmes. This exercise brought out the fact that some of the laboratories need to improve their measurement practices to produce reliable data.
Název v anglickém jazyce
International Intercomparison and Quality Assessment of Passive and Active 222Rn Measuring Devices in the Asia-Pacific Region
Popis výsledku anglicky
Intercomparison exercise is an integral part of the quality assurance programmes in 222Rn measurements using active and passive devices. Ensuring the accuracy of data generated through measurements necessitates periodic performance checks. To achieve harmonization of methods, quantify biases and errors in measurements, and identify the reasons for discrepancies, there is a pressing need for periodic intercomparison exercises. To address this need of numerous laboratories, particularly in the Asia-Pacific region, a calibration facility for 222Rn measuring devices has been established at the Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, India. An international intercomparison exercise for the 222Rn measuring devices was conducted at this facility in the year 2022 with the participation of 10 laboratories from six countries. A total of 354 devices (comprising of both active and passive detectors) were subjected to intercomparison measurements by exposing them to three concentration levels: (5.97 ± 0.29) × 103 Bq m−3, (0.70 ± 0.09) × 103 Bq m−3 and (2.02 ± 0.20) × 103 Bq m−3 in separate experiments and the exposure durations were 7 days, 15 days, and 10 days respectively. The performance of each laboratory was evaluated following the criterion adopted by the International Atomic Energy Agency (IAEA) in its worldwide proficiency test programmes. This exercise brought out the fact that some of the laboratories need to improve their measurement practices to produce reliable data.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
1879-0925
Svazek periodika
178
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
001320653700001
EID výsledku v databázi Scopus
2-s2.0-85204187458