Use of relocation device at scanning of polymeric material surface quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28110%2F14%3A43873142" target="_blank" >RIV/70883521:28110/14:43873142 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.693.243" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.693.243</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.693.243" target="_blank" >10.4028/www.scientific.net/AMM.693.243</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of relocation device at scanning of polymeric material surface quality
Popis výsledku v původním jazyce
Nowadays, manufacturers and users of parts made of polymeric materials make increasing demands on surface quality of these parts. In order to fulfill these claims, it is necessary to use not only the quality measurement systems for surface quality inspection, but also suitable products that allow to set up the inspected polymeric component properly set up to the measuring system scanner. However, it is not sufficient. Due to the requirements of the customers or the production it is often necessary to repeat the surface quality measurement, which is more and more often done in 3D; that might be quite difficult. Except for special cases there should not be any marks done by the inspection workplace which might lower the inspected surface quality. Therefore it is not suitable to make mechanical marks such as scratch, ridge, etc. On the other hand, other types of marks done by non-invasive method, such as sticking paper marks, measuring cross, etc. is also not admissible as there might res
Název v anglickém jazyce
Use of relocation device at scanning of polymeric material surface quality
Popis výsledku anglicky
Nowadays, manufacturers and users of parts made of polymeric materials make increasing demands on surface quality of these parts. In order to fulfill these claims, it is necessary to use not only the quality measurement systems for surface quality inspection, but also suitable products that allow to set up the inspected polymeric component properly set up to the measuring system scanner. However, it is not sufficient. Due to the requirements of the customers or the production it is often necessary to repeat the surface quality measurement, which is more and more often done in 3D; that might be quite difficult. Except for special cases there should not be any marks done by the inspection workplace which might lower the inspected surface quality. Therefore it is not suitable to make mechanical marks such as scratch, ridge, etc. On the other hand, other types of marks done by non-invasive method, such as sticking paper marks, measuring cross, etc. is also not admissible as there might res
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1660-9336
e-ISSN
—
Svazek periodika
693
Číslo periodika v rámci svazku
Neuveden
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
243-246
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—