Volume changes measurement of elastomers using 3D DIC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28110%2F23%3A63567678" target="_blank" >RIV/70883521:28110/23:63567678 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.14311/APP.2023.42.0046" target="_blank" >http://dx.doi.org/10.14311/APP.2023.42.0046</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2023.42.0046" target="_blank" >10.14311/APP.2023.42.0046</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Volume changes measurement of elastomers using 3D DIC
Popis výsledku v původním jazyce
The presented research aims at measuring the volume changes of elastomers using digital image correlation (DIC) in the 3D configuration (stereo DIC). The deformation measurement method in stereo configuration was applied during the mechanical testing of two types of test specimens (dumbbells, cylinders) in uniaxial tension. In this configuration, two cameras were used. The test specimens were measured up to a specified strain value, and the measured data were used to obtain the strain dependence of Poisson’s ratio and the bulk modulus, which are crucial for hyperelastic models. The measurement results reveal that the stereo DIC method provides relatively less scattered data in the low-strain regions for dumbbell-shaped test specimens and is suitable for measuring various test specimen shapes.
Název v anglickém jazyce
Volume changes measurement of elastomers using 3D DIC
Popis výsledku anglicky
The presented research aims at measuring the volume changes of elastomers using digital image correlation (DIC) in the 3D configuration (stereo DIC). The deformation measurement method in stereo configuration was applied during the mechanical testing of two types of test specimens (dumbbells, cylinders) in uniaxial tension. In this configuration, two cameras were used. The test specimens were measured up to a specified strain value, and the measured data were used to obtain the strain dependence of Poisson’s ratio and the bulk modulus, which are crucial for hyperelastic models. The measurement results reveal that the stereo DIC method provides relatively less scattered data in the low-strain regions for dumbbell-shaped test specimens and is suitable for measuring various test specimen shapes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Polytechnica CTU Proceedings
ISBN
978-80-01-07237-0
ISSN
2336-5382
e-ISSN
—
Počet stran výsledku
5
Strana od-do
46-50
Název nakladatele
Czech Technical University
Místo vydání
Praha
Místo konání akce
Telč
Datum konání akce
11. 6. 2023
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—