Local Muscular Load Measurement with the Help of a Datalogger
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28120%2F17%3A63517982" target="_blank" >RIV/70883521:28120/17:63517982 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.12700/APH.14.8.2017.8.12" target="_blank" >http://dx.doi.org/10.12700/APH.14.8.2017.8.12</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.12700/APH.14.8.2017.8.12" target="_blank" >10.12700/APH.14.8.2017.8.12</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Local Muscular Load Measurement with the Help of a Datalogger
Popis výsledku v původním jazyce
The aim of this research was the development and verification of the local muscular load measuring methodology as a valid and recognized measurement in order to subsequently strengthen injury prevention of occupational diseases among workers of both manufacturing and non-manufacturing companies. A milestone in the project was construction of a measuring device to obtain data for evaluating local muscular load with the use of force measurement, frequency of movements and positions and a device called datalogger. This measuring device was then tested and its functionality has been successfully proved in 40 measurements in both manufacturing and non-manufacturing enterprises. The reason for the development of this equipment was especially a requirement to learn the load (force generation) of the individual fingers when operators work, implemented by different grips, e. g. tridigital, pentadigital and so on. Such quantification is not possible with the current EMG method. The developed equipment had to be validated with existing certified methodology called electromyography, which allows only summative evaluation. The results of correlations of both measurements while evaluating the local muscular load are analyzed in this article. The aim of this paper is also to describe how the new device was developed and tested: the Datalogger for measuring local muscular load and its advantages and limitations. Based on the defense carried out, the Industrial Property Office subsequently issued a letters patent for the invention with a number PV 2015-820 earlier this year. The invention relates to an ergonomic device developed for monitoring of local muscular load, and is especially useful in workplaces where there is increased stress, particularly stress on your hands when multiple/repetitive movements, often involving spending increased muscle strength. Measurements can also be made for operators wearing different preservative gloves commonly used in practice. In this article the authors will introduce not only new patented apparatus itself, but a new methodology for local muscular load measuring with the datalogger as well.
Název v anglickém jazyce
Local Muscular Load Measurement with the Help of a Datalogger
Popis výsledku anglicky
The aim of this research was the development and verification of the local muscular load measuring methodology as a valid and recognized measurement in order to subsequently strengthen injury prevention of occupational diseases among workers of both manufacturing and non-manufacturing companies. A milestone in the project was construction of a measuring device to obtain data for evaluating local muscular load with the use of force measurement, frequency of movements and positions and a device called datalogger. This measuring device was then tested and its functionality has been successfully proved in 40 measurements in both manufacturing and non-manufacturing enterprises. The reason for the development of this equipment was especially a requirement to learn the load (force generation) of the individual fingers when operators work, implemented by different grips, e. g. tridigital, pentadigital and so on. Such quantification is not possible with the current EMG method. The developed equipment had to be validated with existing certified methodology called electromyography, which allows only summative evaluation. The results of correlations of both measurements while evaluating the local muscular load are analyzed in this article. The aim of this paper is also to describe how the new device was developed and tested: the Datalogger for measuring local muscular load and its advantages and limitations. Based on the defense carried out, the Industrial Property Office subsequently issued a letters patent for the invention with a number PV 2015-820 earlier this year. The invention relates to an ergonomic device developed for monitoring of local muscular load, and is especially useful in workplaces where there is increased stress, particularly stress on your hands when multiple/repetitive movements, often involving spending increased muscle strength. Measurements can also be made for operators wearing different preservative gloves commonly used in practice. In this article the authors will introduce not only new patented apparatus itself, but a new methodology for local muscular load measuring with the datalogger as well.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20206 - Computer hardware and architecture
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica Hungarica
ISSN
1785-8860
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
20
Strana od-do
215-234
Kód UT WoS článku
000423415200012
EID výsledku v databázi Scopus
—