Vzduchotechnický systém, jako součást integrovaného řídícího systému v budovách
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F06%3A63504400" target="_blank" >RIV/70883521:28140/06:63504400 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
AIRCONDITIONAL SYSTEMS - PART OF INTEGRATED CONTROL SYSTEMS IN BUILDINGS
Popis výsledku v původním jazyce
The article deals with the control of air-conditional systems and monitoring of their function in the frame of integrated systems in buildings, particularly focussed on residential premises (buildings for living etc.). Specifically in residential premises there exists a great potential for application of fully integrated control systems. Well managed HVAC systems play a substantial role in energy management of buidings as well. Tasks for the smart houses and derived requirements for control systems arestated in SmartHouse Code of Practice CWA 50487:2005 of CENELEC. Open control systems only could meet these set of requirements. Basic requirements for existing control systems and their main features and avaluation are briefly described in the article.Farther the impact of control system of HVAC on energy consumption is mentioned in the article.
Název v anglickém jazyce
AIRCONDITIONAL SYSTEMS - PART OF INTEGRATED CONTROL SYSTEMS IN BUILDINGS
Popis výsledku anglicky
The article deals with the control of air-conditional systems and monitoring of their function in the frame of integrated systems in buildings, particularly focussed on residential premises (buildings for living etc.). Specifically in residential premises there exists a great potential for application of fully integrated control systems. Well managed HVAC systems play a substantial role in energy management of buidings as well. Tasks for the smart houses and derived requirements for control systems arestated in SmartHouse Code of Practice CWA 50487:2005 of CENELEC. Open control systems only could meet these set of requirements. Basic requirements for existing control systems and their main features and avaluation are briefly described in the article.Farther the impact of control system of HVAC on energy consumption is mentioned in the article.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 17th AIR-CONDITIONING AND VENTILATION CONFERENCE 2006
ISBN
80-02-01811-7
ISSN
—
e-ISSN
—
Počet stran výsledku
503
Strana od-do
387-392
Název nakladatele
Společnost pro techniku prostředí
Místo vydání
Praha
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—