Použití prostředí Control Web pro řízení laboratorních modelů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F07%3A63505882" target="_blank" >RIV/70883521:28140/07:63505882 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of the Control Web Software Environment in Laboratory Model Control
Popis výsledku v původním jazyce
This paper deals with design of a new application including device driver for Control Web 5 software environment which is universal tool for design of visualization and control applications using object-oriented component architecture. Thanks to standardized driver interface developer can create driver for any device which is necessary in the controlled system. These properties are very advantageous during implementation in control of real processes such as real laboratory models for automatic-control-theory education support. Each model is connected with personal computer via portable data acquisition unit utilizing RS232 interface. Developed device driver provides all standard functions needed for its full functionality under Control Web driver interface version 3 thus it can work with all next versions. Its correct function was verified by control of educational time-delay heating plant model.
Název v anglickém jazyce
Utilization of the Control Web Software Environment in Laboratory Model Control
Popis výsledku anglicky
This paper deals with design of a new application including device driver for Control Web 5 software environment which is universal tool for design of visualization and control applications using object-oriented component architecture. Thanks to standardized driver interface developer can create driver for any device which is necessary in the controlled system. These properties are very advantageous during implementation in control of real processes such as real laboratory models for automatic-control-theory education support. Each model is connected with personal computer via portable data acquisition unit utilizing RS232 interface. Developed device driver provides all standard functions needed for its full functionality under Control Web driver interface version 3 thus it can work with all next versions. Its correct function was verified by control of educational time-delay heating plant model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 16th International Conference on Process Control´07
ISBN
978-80-227-2677-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Slovenská technická univerzita v Bratislave
Místo vydání
Bratislava
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—