Dual axis wireless force measureemnt study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F10%3A63508996" target="_blank" >RIV/70883521:28140/10:63508996 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dual axis wireless force measureemnt study
Popis výsledku v původním jazyce
Over the couple of years, wireless measurements and wireless networks have soared in all sorts of new applications due to its advantages which mean low cost, low power consumption, as well as wireless connection. Since 1990s a new era of sensor has developed with an advance of a MEMS technology. A convenient means of measuring a small force consists of applying the force to a strain gauge bridge sensor and signal condition circuit is proposed. The test measurement is based on the Freescale?s ZSTAR3 kitcollaborated with two ? axes strain gauge sensor by including its signal conditioning circuit. An experimental result relieves that the relationship between applied force and measured raw value is merely linear in every case of test. Maximum estimated standard deviations based on a sample calculated to be 0.411% in X ? axis, 0.3% in Y ? axis measurement.
Název v anglickém jazyce
Dual axis wireless force measureemnt study
Popis výsledku anglicky
Over the couple of years, wireless measurements and wireless networks have soared in all sorts of new applications due to its advantages which mean low cost, low power consumption, as well as wireless connection. Since 1990s a new era of sensor has developed with an advance of a MEMS technology. A convenient means of measuring a small force consists of applying the force to a strain gauge bridge sensor and signal condition circuit is proposed. The test measurement is based on the Freescale?s ZSTAR3 kitcollaborated with two ? axes strain gauge sensor by including its signal conditioning circuit. An experimental result relieves that the relationship between applied force and measured raw value is merely linear in every case of test. Maximum estimated standard deviations based on a sample calculated to be 0.411% in X ? axis, 0.3% in Y ? axis measurement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Summaries volume 9th International Conference Process Control 2010
ISBN
978-80-7399-951-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Tribun EU
Místo vydání
Brno
Místo konání akce
Kouty nad Desnou
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—