STUDY AND RECOMMENDED SPECIFICATIONS FOR PROBES USED TO MEASURE SECURITY SYSTEMS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F11%3A43866360" target="_blank" >RIV/70883521:28140/11:43866360 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STUDY AND RECOMMENDED SPECIFICATIONS FOR PROBES USED TO MEASURE SECURITY SYSTEMS
Popis výsledku v původním jazyce
This paper brings you the essential knowledge and findings regarding the measurement of microwave antennas parameters in near zone. The goal of this report is to give you an overview of advantages and disadvantages of the near zone measurement process and comparison with measurements performed in distant zone. Probes with low gain offer advantages from the calculation point of view, because is often not necessary to perform compensation of the probe during calculation. That is true mostly for cylindrical and spherical monitoring/scanning (spherical monitoring is even less sensitive to the probe influence then cylindrical monitoring). Using probes with two orthogonally polarized signals, to ensure monitoring/scanning of two data files during one scan, will shorten the time to half, which is necessary for data collection in comparison with traditional monitoring/scanning with one output probe. This paper gives you several typical samples of probes with one or two outputs for reception of
Název v anglickém jazyce
STUDY AND RECOMMENDED SPECIFICATIONS FOR PROBES USED TO MEASURE SECURITY SYSTEMS
Popis výsledku anglicky
This paper brings you the essential knowledge and findings regarding the measurement of microwave antennas parameters in near zone. The goal of this report is to give you an overview of advantages and disadvantages of the near zone measurement process and comparison with measurements performed in distant zone. Probes with low gain offer advantages from the calculation point of view, because is often not necessary to perform compensation of the probe during calculation. That is true mostly for cylindrical and spherical monitoring/scanning (spherical monitoring is even less sensitive to the probe influence then cylindrical monitoring). Using probes with two orthogonally polarized signals, to ensure monitoring/scanning of two data files during one scan, will shorten the time to half, which is necessary for data collection in comparison with traditional monitoring/scanning with one output probe. This paper gives you several typical samples of probes with one or two outputs for reception of
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Military Technologies 2011
ISBN
978-80-7231-787-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1199-1203
Název nakladatele
Univerzita obrany
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
10. 5. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—